The power supply/cooling modules are located to the left and right of the LCCs. The units integrate independent power supply and two dual-blower cooling assemblies into a single module.
Each power supply is an auto-ranging, power-factor-corrected, multi-output, offline converter with its own line cord. Each supply supports a fully configured DAE and shares load currents with the other supply. The drives and LCCs have individual soft-start switches that protect the disk drives and LCCs if they are installed while the disk enclosure is powered up. The enclosure cooling system includes two dual-blower modules.
Figure 1 shows an example of a 2U, 25-drive DAE AC power supply/cooling module with a power in (recessed) connector (plug) and status LEDs.
Location | Description | Location | Description |
---|---|---|---|
Ejector latch handle | Power supply/cooling module fault LED | ||
AC power LED (input) | Grounding screw | ||
DC power LED (output) | LCC B AC power supply power in (recessed plug) |
LED | Location | Color | State | Description |
---|---|---|---|---|
AC power LED (input) | Green | On | AC power on | |
— | Off | AC power off, verify source power | ||
DC power LED (output) | Green | On | DC power on | |
— | Off | DC power off, verify source power | ||
Power supply/cooling module fault LED | Amber | On | Fault | |
Blinking | During power shutdown and during overvoltage (OVP) and undervoltage protection (UVP) fault | |||