Dell Unity™ All Flash and Unity Hybrid Hardware Information Guide

Cabling for x4 connections

About this task

The drives in the DPE are internally connected to the first back-end bus, which is bus 0. To maintain balance, the first DAE connected to the array should be connected to back-end bus 1. If the array only has 2 back end busses (0 and 1) then you should add DAEs by alternating between bus 0 and bus 1 to maintain an even distribution, or balance of drives over the busses.

If the array has a 4-port SAS I/O module, this would create additional back-end bus numbers 2 through 5. Maintain the same type of even distribution of drives over all of the back-end busses.

This section provides three different ways to connect the DAE to the array with an x4 connection.

  • Connecting to back-end bus 1
  • Connecting to back-end bus 0
  • Connecting to a port on the SAS I/O module

Each installation may be different. Choose the connection option that suits your needs.

Procedure

  • Connect to back-end bus 1: To connect the first optional expansion DAE to back-end port 1 of the DPE to create back-end bus 1 (BE1) and designate this DAE as Enclosure Address 0 of this bus. We refer to the address of this enclosure as BE1 EA0 (1_0):
    1. Label a pair of mini-SAS HD cables using the blue labels shown here.
      Expansion port cable labeling details Primary port cable labeling details
      Label part number Label Port Label part number Label Port
      046-001-562 SP A SAS 1 046-021-012 LCC A Port A
      046-003-750 SP B SAS 1 046-021-013 LCC B Port A
    2. Connect the ports as follows:
      • Connect BE port 1 on SP A (the bottom storage processor of the DPE) to port A of link control card A (LCC A) on the right side of the DAE.
      • Connect BE port 1 on SP B (the top storage processor of the DPE) to port A of link control card B (LCC B) on the left side of the DAE.
  • Connect to back-end bus 0: To connect the second optional expansion DAE to the DPE expansion port 0 to extend back-end bus 0 (BE0) and designate this DAE as Enclosure Address 1 of this bus. We refer to the address of this enclosure as BE0 EA1 (0_1):
    1. Label a pair of mini-SAS HD cables using the orange labels shown here.
      Expansion port cable labeling details Primary port cable labeling details
      Label part number Label Port Label part number Label Port
      046-001-561 SP A SAS 0 046-021-010 LCC A Port A
      046-003-489 SP B SAS 0 046-021-011 LCC B Port A
    2. Connect the ports as follows:
      • Connect BE port 0 on SP A (the bottom storage processor of the DPE) to port A of link control card A (LCC A) on the right side of the DAE.
      • Connect port 0 on SP B (the top storage processor of the DPE) to port A of link control card B (LCC B) on the left side of the DAE .
  • Connect to the 4-port SAS back-end I/O module: To connect the DAE to a BE port in the SAS I/O module of the storage processor, cable the DAE to the first available port in the 12-Gb/s SAS I/O module. Use the same port on each storage processor's SAS I/O module. This SAS I/O module can be used to create back-end bus 2 through 5, (BE2 through BE5):
    NOTE:The optional back-end 12-Gb/s SAS module is not supported on all Unity storage systems.
    NOTE:Adding a new 12-Gb/s SAS I/O module requires a coordinated restart of the array. Refer to Adding an optional I/O module for more information.
    1. Label a pair of mini-SAS HD cables using the appropriate labels (black, green, brown, or blue) shown here.
      Expansion port cable labeling details Primary port cable labeling details
      Label part number Label Port Label part number Label Port
      046-005-679 SP A A0 PORT 0 046-021-16 LCC A Port A
      046-005-718 SP B B0 PORT 0 046-021-017 LCC B Port A
      046-005-711 SP A A0 PORT 1 046-021-018 LCC A Port A
      046-005-719 SP B B0 PORT 1 046-021-019 LCC B Port A
      046-005-935 SP A A0 PORT 2 046-021-020 LCC A Port A
      046-005-937 SP B B0 PORT 2 046-021-021 LCC B Port A
      046-005-936 SP A A0 PORT 3 046-021-022 LCC A Port A
      046-005-938 SP B B0 PORT 3 046-021-023 LCC B Port A
    2. For SP A, connect the DAE cable to the lowest available port in the SAS module in the bottom storage processor of the DPE to port A on link control card AA/A (LCC A) on the right side of the DAE.
    3. For SP B, connect the DAE cable to the lowest available port in the SAS module in the top storage processor of the DPE to port A on link control card BB/B (LCC B) on the left side of the DAE.

Example

Figure 1. x4 cabling example
An example of x4 cabling

Diesen Inhalt bewerten

Präzise
Nützlich
Leicht verständlich
War dieser Artikel hilfreich?
0/3000 characters
  Bitte geben Sie eine Bewertung ab (1 bis 5 Sterne).
  Bitte geben Sie eine Bewertung ab (1 bis 5 Sterne).
  Bitte geben Sie eine Bewertung ab (1 bis 5 Sterne).
  Bitte geben Sie an, ob der Artikel hilfreich war.
  Die folgenden Sonderzeichen dürfen in Kommentaren nicht verwendet werden: <>()\