Dell Unity™ All Flash and Unity Hybrid Hardware Information Guide

Cabling for x8 connections

Prerequisites

As previously noted, if you are connecting the DAE to a 4-port SAS I/O module that requires x8 connectivity, you must insert the SAS cable into the 4-port SAS I/O module before persisting it. The 4-port SAS I/O module must be persisted with the cable inserted for x8 connectivity. If the SAS back-end I/O module is powered on and persisted without any cables inserted, it is automatically set at x4 and cannot be used for x8 lane cabling.

NOTE:x8 connections can only be made using the 4-port back-end SAS I/O module. Never use ports 1 and 2 for x8 connections.

Procedure

Connect to the 4-port SAS back-end I/O module: Insert SAS cables into ports 0 and 1 or ports 2 and 3 of the 4-port SAS I/O modules in the storage processor, if they are not connected already. For consistency and clarity, use ports 0 and 1 first. This will create BE bus 2. The next configured x8 bus using ports 2 and 3 will create BE 4.
  1. Label a pair of mini-SAS HD cables using the black or green labels.
    The labels used depend upon how the back-end ports are configured.
  2. Connect the ports as follows:
    • Ensure that the SAS cable is inserted into ports 0 and 1 or ports 2 and 3 of the SP A SAS module, located in the bottom storage processor of the DPE. Connect the cable to ports AA/A of link control card A (LCC A), located on the right side of the DAE.
    • Ensure that the SAS cable is inserted into ports 0 and 1 or ports 2 and 3 of SP B SAS module, located in the top storage processor of the DPE. Connect the cable to ports AA/A of link control card B (LCC B), located on the left side of the DAE.

Example

Figure 1. x8 cabling example
An example of proper cabling for x8 systems.

Diesen Inhalt bewerten

Präzise
Nützlich
Leicht verständlich
War dieser Artikel hilfreich?
0/3000 characters
  Bitte geben Sie eine Bewertung ab (1 bis 5 Sterne).
  Bitte geben Sie eine Bewertung ab (1 bis 5 Sterne).
  Bitte geben Sie eine Bewertung ab (1 bis 5 Sterne).
  Bitte geben Sie an, ob der Artikel hilfreich war.
  Die folgenden Sonderzeichen dürfen in Kommentaren nicht verwendet werden: <>()\