Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell Configuration Guide for the S4048–ON System 9.14.2.6

PDF

Configuring Detection and Ports for Dell Compellent Arrays

To configure a port connected to a Dell Compellent storage array, use the following command.

Configure a port connected to a Dell Compellent storage array.
INTERFACE Configuration mode
iscsi profile-compellent
The command configures a port for the best iSCSI traffic conditions.
The following message displays the first time you use the iscsi profile-compellent command to configure a port connected to a Dell Compellent storage array and describes the configuration changes that are automatically performed:
%STKUNIT0-M:CP %IFMGR-5-IFM_ISCSI_AUTO_CONFIG: This switch is being configured for optimal
conditions to support iSCSI traffic which will cause some automatic configuration to occur
including jumbo frames and flow-control on all ports; no storm control and spanning-tree port
fast to be enabled on the port of detection.
After you execute the iscsi profile-compellent command, the following actions occur:
  • Jumbo frame size is set to the maximum for all interfaces on all ports and port-channels, if it is not already enabled.
  • Spanning-tree portfast is enabled on the interface.
  • Unicast storm control is disabled on the interface.
Enter the iscsi profile-compellent command in INTERFACE Configuration mode.