Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Event and Error Message Reference Guide for 13th Generation Dell PowerEdge ServersVersion 1.2

PDF

BIOS Event Messages

BIOS001

Message
The command was successful
Detailed Description
The command was successful.
Recommended Response Action
No response action is required.
Category
Configuration (BIOS = BIOS Management)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

BIOS002

Message
Resource allocation failure.
Detailed Description
Unable to allocate required memory to perform the requested operation; see the inserted comment.
Recommended Response Action
Power cycle system and reapply firmware packages for Lifecycle Controller and iDRAC.
Category
Configuration (BIOS = BIOS Management)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

BIOS003

Message
Missing required parameter. Refer to the inserted comment.
Detailed Description
An invalid number of arguments was passed to the method.
Recommended Response Action
Enter all the required command parameters. Check documentation and try again.
Category
Configuration (BIOS = BIOS Management)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

BIOS004

Message
Invalid parameter value for arg1
Arguments
arg1 = attribute name
Detailed Description
The value for the specified parameter is invalid.
Recommended Response Action
Verify that parameter values passed to the method are entered as they appear in the enumeration and parameter data type matches the documentation.
Category
Configuration (BIOS = BIOS Management)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

BIOS005

Message
Mismatch in AttributeName and AttributeValue count
Detailed Description
The number of AttributeName and AttributeValue parameters do not match.
Recommended Response Action
Enter the same number of parameters for AttributeName and AttributeValue. Refer to documentation for method input parameter details.
Category
Configuration (BIOS = BIOS Management)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

BIOS006

Message
Configuration job already created, cannot set attribute on specified target until existing job is completed or is cancelled
Detailed Description
A configuration job is already created on the specified target. No further command is allowed until the existing job succeeds or the job is cancelled.
Recommended Response Action
Wait for the job to complete. To continue with more set operations on the specified target, cancel the job and proceed.
Category
Configuration (BIOS = BIOS Management)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

BIOS007

Message
Configuration job already created, cannot create another configuration job on specified target until existing job is completed or is cancelled
Detailed Description
A configuration job is already created on the specified target. No further command is allowed until the existing job succeeds or the job is cancelled.
Recommended Response Action
Wait for the job to complete. To continue with more set operations on the specified target, cancel the job and proceed.
Category
Configuration (BIOS = BIOS Management)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

BIOS008

Message
No pending data present to create a Configuration job
Detailed Description
No changes are available between the previous configuration and the current configuration. To create a configuration job, at least one attribute should be changed.
Recommended Response Action
Change the configuration of one or more attributes and then create a configuration job.
Category
Configuration (BIOS = BIOS Management)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

BIOS009

Message
Lifecycle Controller is currently in use.
Detailed Description
Lifecycle Controller cannot gain access to internal storage because of use by another application or operation.
Recommended Response Action
Wait for the current Lifecycle Controller operation to complete. Verify that the system is 1) Not currently in Lifecycle Controller Unified Server Configurator utility 2) Waiting for user intervention at F1/F2 POST error 3) Not in any of the device or controller Option ROMs and retry the operation.
Category
Configuration (BIOS = BIOS Management)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

BIOS010

Message
Lifecycle Controller is not enabled, cannot create Configuration job.
Detailed Description
For 11G systems: System Services must be enabled to perform the requested operation. System Services has been disabled through the iDRAC configuration utility accessed by pressing CTRL+E on boot up or through a remote operation. For 12G systems: Lifecycle Controller must be enabled to perform the requested operation. Lifecycle Controller has been disabled by pressing F2 Setup, selecting iDRAC Configuration, and selecting Lifecycle Controller Settings on boot up or through a remote operation.
Recommended Response Action
For 11G systems: Use the iDRAC configuration utility to enable the System Services by pressing on the CTRL+E option on boot up at the targeted system. For 12G systems: Use F2 Setup, select iDRAC Configuration, and select Lifecycle Controller Settings, to enable the Lifecycle Controller on boot up of the targeted system.
Category
Configuration (BIOS = BIOS Management)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

BIOS011

Message
Configuration job already created, pending data cannot be deleted
Detailed Description
Configuration job already created on the specified target. No further command is allowed until the existing job is completed.
Recommended Response Action
Cancel the configuration job or wait for the job to complete. Refer to documentation on job cancellation.
Category
Configuration (BIOS = BIOS Management)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

BIOS012

Message
No pending data to delete.
Detailed Description
No changes to BIOS attribute data are available between the previous configuration and the current configuration.
Recommended Response Action
No response action is required.
Category
Configuration (BIOS = BIOS Management)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

BIOS013

Message
Invalid AttributeName arg1
Arguments
arg1 = attribute name
Detailed Description
An unknown AttributeName was specified in the operation.
Recommended Response Action
Enter the correct AttributeName available in the system. Refer to the enumeration response for desired attribute.
Category
Configuration (BIOS = BIOS Management)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

BIOS014

Message
Invalid AttributeValue for AttributeName: arg1
Arguments
arg1 = attribute name
Detailed Description
AttributeValue may be invalid because of the following causes: 1) Length of new AttributeValue is not within required minimum length and maximum length 2) Value of new AttributeValue is not within required LowerBound and UpperBound 3) Value of new Attributevalue is not one of the possible values.
Recommended Response Action
Refer to the documentation on valid Attribute values.
Category
Configuration (BIOS = BIOS Management)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

BIOS015

Message
AttributeValue cannot be changed to read only AttributeName arg1 .
Arguments
arg1 = attribute name
Detailed Description
A set attribute operation was attempted on a read only attribute.
Recommended Response Action
No response action is required.
Category
Configuration (BIOS = BIOS Management)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

BIOS016

Message
AttributeValue cannot be changed for disabled AttributeName arg1 .
Arguments
arg1 = attribute name
Detailed Description
A set attribute operation was attempted on a disabled attribute.
Recommended Response Action
No response action is required.
Category
Configuration (BIOS = BIOS Management)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

BIOS017

Message
Unable to delete vFlash pending one-time boot configuration
Detailed Description
Unable to delete vFlash pending one-time boot configuration.
Recommended Response Action
Remove AC power from system and after restoring AC power, retry the operation.
Category
Configuration (BIOS = BIOS Management)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

BIOS018

Message
Invalid BIOS Password.
Detailed Description
The BIOS password specified in the operation is not valid. A valid BIOS password must be made from the following: 0 to 32 characters in length, numbers 0 to 9, lowercase letters a to z, special characters <>|-,+./;[\].
Recommended Response Action
Retry the operation with a BIOS password that conforms with system BIOS password requirements.
Category
Configuration (BIOS = BIOS Management)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

BIOS021

Message
Cannot authenticate BIOS password.
Detailed Description
The old BIOS password specified in the change BIOS password operation was incorrect.
Recommended Response Action
Retry the operation with correct old BIOS password.
Category
Configuration (BIOS = BIOS Management)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

BIOS022

Message
Cannot set the BIOS password. Password is disabled due to a jumper setting on the motherboard.
Detailed Description
The BIOS password is disabled in the hardware using a jumper and can not be set. See the system owners manual for jumper location.
Recommended Response Action
Change the jumper setting on the system board to enable changing the BIOS password.
Category
Configuration (BIOS = BIOS Management)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

BIOS023

Message
Cannot perform the operation due to an unknown error in iDRAC.
Detailed Description
An unrecoverable error occurred in the operation while communicating with iDRAC.
Recommended Response Action
Retry the operation. If the issue continues, reset the iDRAC.
Category
Configuration (BIOS = BIOS Management)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

BIOS024

Message
The set operation did not complete successfully as the attribute is read-only.
Detailed Description
The operation cannot run as the attribute value cannot be modified.
Recommended Response Action
For more information on the attribute, see Lifecycle Controller-Remote Services documentation.
Category
Configuration (BIOS = BIOS Management)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

BIOS025

Message
Unable set the BIOS password as the BIOS password status is locked.
Detailed Description
The status of the password is Locked in BIOS and must be set to Unlocked for the operation to succeed.
Recommended Response Action
Change BIOS password status in the BIOS setup from Locked to Unlocked and retry the operation.
Category
Configuration (BIOS = BIOS Management)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

BIOS026

Message
Password status cannot be set to locked when a System Password change is pending.
Detailed Description
The status of the Password cannot be set to locked, because currently there is a System Password change is pending.
Recommended Response Action
Wait until the pending System Password change is applied or delete the pending System Password change and retry the operation.
Category
Configuration (BIOS = BIOS Management)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

BIOS027

Message
Unable to change the BIOS password because the password is currently being configured using plain text. Unable to set the attribute arg1 .
Arguments
arg1 = attribute name
Detailed Description
The attribute identified in the message cannot be set, because the password is currently being reset by using plain text. The BIOS password cannot be simultaneously configured by using plain text and a hash.
Recommended Response Action
Wait until the current password configuration process is completed, and then retry the operation.
Category
Configuration (BIOS = BIOS Management)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC            

BIOS028

Message
Unable to change the BIOS password using plain text because the password is currently being configured using a hash.
Detailed Description
The BIOS password cannot be simultaneously configured by using plain text and a hash.
Recommended Response Action
Wait until the current password configuration process is completed and retry the operation.
Category
Configuration (BIOS = BIOS Management)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

BIOS029

Message
Unable to change the BIOS password because an Export Server Profile operation is already running.
Detailed Description
The BIOS password cannot be configured because an Export Server Profile operation is already running.
Recommended Response Action
Wait until the current export operation is completed, and then retry the operation.
Category
Configuration (BIOS = BIOS Management)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

BIOS030

Message
Unable to change the BIOS password because an Import Server Profile operation is already running.
Detailed Description
The BIOS password cannot be configured because an Import Server Profile operation is already running.
Recommended Response Action
Wait until the current import operation is completed, and then retry the operation.
Category
Configuration (BIOS = BIOS Management)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

BIOS101

Message
Unable to read or change any of the system BIOS configuration settings.
Detailed Description
The system configuration data that BIOS exposes to Server Administrator is malformed or not available and Server Administrator is unable to read or change any of the system BIOS configuration setttings.
Recommended Response Action
Power cycle the system and retry the operation. If the problem persists, reinstall the BIOS firmware Update Package.
Category
Configuration (BIOS = BIOS Management)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

BIOS102

Message
A system BIOS update is scheduled that requires a reboot.
Detailed Description
A BIOS update job is scheduled through the remote access controller, and the system must be rebooted to apply the update.
Recommended Response Action
Reboot the system to apply the BIOS update.
Category
Audit (BIOS = BIOS Management)
Severity
Severity 3 (Informational)
OMSA Event ID
5002
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

BIOS103

Message
A previously scheduled system BIOS update is canceled.
Detailed Description
A previously scheduled BIOS update job is cancelled.
Recommended Response Action
No response action is required.
Category
Audit (BIOS = BIOS Management)
Severity
Severity 3 (Informational)
OMSA Event ID
5003
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\