You can configure Network Management Station clients as SNMPv2 trap recipients for the SNMP traps that are generated by the ECS fabric using SNMPv2 standard messaging.
Prerequisites
This operation requires the System Administrator role in ECS.
Steps
In the ECS Portal, select
Settings > Event Notification.
On the
Event Notification page, the
SNMP tab displays by default and lists the SNMP servers that have been added to ECS.
To add an SNMP server target, click
New Target.
The
New SNMP Target page is displayed.
On the
New SNMP Target page, complete the following steps:
In the
FQDN/IP field, type the Fully Qualified Domain Name or IP address for the SNMP v2c trap recipient node that runs the
snmptrapd server.
In the
Port field, type the port number of the SNMP v2c
snmptrapd running on the Network Management Station clients.
The default port number is
162.
In the
Version field, select
SNMPv2.
In the
Community Name field, type the SNMP community name.
Both the SNMP server and any Network Management Station clients that access it must use the same community name to ensure authentic SNMP message traffic, as defined by the standards in RFC 1157 and RFC 3584.
The default community name is
public.
Click
Save.