Integrated Dell Remote Access Controller 9 Version 3.30.30.30 User's Guide

Configuring backplane mode using web interface

To configure backplane mode using iDRAC web interface:
  1. In the iDRAC web interface, go to Configuration > Storage Configuration > Enclosures Configuration.
  2. From the Controller menu, select the controller to configure its associated enclosures.
  3. From the Action drop-down menu, select Edit Enclosure Mode.
    The Edit Enclosure Mode page is displayed.
  4. In the Current Value column, select the required enclosure mode for the backplane or enclosure. The options are:
    • Unified Mode
    • Split Mode
    • Split Mode 4:20
    • Split Mode 8:16
    • Split Mode 16:8
    • Split Mode 20:4
    NOTE For C6420, the available modes are: Split Mode and Split Mode-6:6:6:6.
    For R740xd and R940, power cycle of the server is needed to apply the new backplane zone and for C6420, A/C cycle (of the blade chassis) to apply the new backplane zone.
  5. Click Add to Pending Operations.
    A job ID is created.
  6. Click Apply Now.
  7. Go to the Job Queue page and verify that it displays the status as Completed for the job.
  8. Power cycle the system for the setting to take effect.