The technical specifications for the SCv2000/SCv2020 storage systems are shown in the following tables.
Drives | |
---|---|
SAS hard drives |
SCv2000
:
Up to 12 3.5-inch SAS hot-swappable hard drives (6.0 Gbps), six drive
minimum
SCv2020 : Up to 24 2.5-inch SAS hot-swappable hard drives (6.0 Gbps), six drive minimum |
Redundant Array of Independent Disks (RAID) | |
---|---|
Controller | Two hot-swappable storage controllers |
Management | RAID management using Dell Storage Manager Client 2016 R2 |
Back-Panel Port Connectors (per Storage Controller ) | |
---|---|
Fibre Channel, iSCSI, or SAS connectors | Connection to a Fibre Channel fabric, iSCSI network, or a direct connection to servers with SAS HBAs |
Ethernet connectors |
MGMT: 1 Gbps or 10 Gbps embedded Ethernet/iSCSI
port used for
Storage Center management
REPL: 1 Gbps or 10 Gbps embedded iSCSI port used for replication to another Storage Center |
SAS connectors | 6 Gbps SAS connectors for SAS port redundancy and additional expansion enclosures |
USB connector |
One USB 3.0 connector used for Storage Center updates |
Serial connector |
Power Supplies | |
---|---|
AC power supply (per power supply) | |
Wattage | 580 W (maximum wattage: 584 W) |
Voltage | 100–240 VAC (7.6–3.0 A) |
Heat dissipation |
SCv2000
:
65 W at 230 VAC and 99 W at 115 VAC
SCv2020 : 65 W at 230 VAC and 99 W at 115 VAC |
Maximum inrush current | Under typical line conditions and over the entire system ambient operating range, the inrush current could reach 45 A per power supply for 40 ms or less |
Available Hard Drive Power (per Slot) | |
---|---|
Supported hard drive power consumption (continuous) | Up to 1.2 A at +5 V
Up to 0.5 A at +12 V |
Physical | |
---|---|
Height | 8.79 cm (3.46 in.) |
Width | 48.2 cm (18.98 in.) |
Depth |
SCv2000
:
57.6 cm (22.67 in.)
SCv2020 : 52.3 cm (20.59 in.) |
Weight (maximum configuration) |
SCv2000
:
28.9 kg (63.9 lb)
SCv2020 : 24 kg (53 lb) |
Weight without drives |
SCv2000
:
20.6 kg (45.4 lb)
SCv2020 : 18.7 kg (41 lb) |
Environmental | |
---|---|
For additional information about environmental measurements for specific storage system configurations, see dell.com/environmental_datasheets. | |
Temperature | |
Operating | 10°C to 35°C (50°F to 95°F) with a maximum temperature gradation of 20°C per hour |
Storage | –40°C to 65°C (–40°F to 149°F) at a maximum altitude of 12,000 m (39,370 ft) |
Relative humidity | |
Operating | 10% to 80% (noncondensing) with 29°C (84.2°F) maximum dew point |
Storage | 5% to 95% (noncondensing) with 33°C (91°F) maximum dew point |
Maximum vibration | |
Operating | 0.21 G at 5–500 Hz for 15 min |
Storage | 1.04 G at 2–200 Hz for 15 min |
Maximum shock | |
Operating | Half-sine shock 5 G +/- 5% with a pulse duration of 10 ms +/- 10% (in operational orientations only) |
Storage | Half-sine shock 30 G +/- 5% with a pulse duration of 10 ms +/- 10% (all sides) |
Altitude | |
Operating | 0 m to 3,048 m (0 ft to 10,000 ft) |
Storage | –300 m to 12,000 m (–1000 ft to 39,370ft) |
Airborne Contaminant Level | |
Class | G1 or lower as defined by ISA-S71.04-1985 |