The following tables provide technical specifications for the SC7020 series storage systems:
Drives | |
---|---|
SC7020: SAS hard drives | Up to 30 2.5-in. SAS hot-swappable HDDs (12 Gb SAS) |
SC7020F: SAS SSDs | Up to 30 2.5-in. SAS hot-swappable SSDs (12 Gb SAS) |
Storage Controllers | |
---|---|
Storage controllers |
Two hot-swappable storage controllers with one mezzanine card and three I/O card slots per storage controller. Each storage controller has an internal battery backup unit. Write cache is mirrored between the two storage controllers. If a power failure occurs, the battery backup unit provides power to the storage controller so that the write cache can be saved to an SSD within the storage controller. |
Storage Connectivity | |
---|---|
Configurations |
SC7020: Supports a total of 606 drives and 192 drives per SAS chain. Each SAS chain supports up to sixteen SC400 expansion enclosures, eight SC420 expansion enclosures, three SC460 expansion enclosures, and two SC280 expansion enclosures. SC7020F: Supports a total of 606 SSDs and up to 192 SSDs per SAS chain. Each SAS chain supports up to eight SC420F expansion enclosure. |
Redundant Array of Independent Disks (RAID) | |
---|---|
Controller | Two hot-swappable storage controllers |
Management | RAID management using the Storage Manager |
Back-Panel Ports Connectors (per Storage Controller) | |
---|---|
Fibre Channel or iSCSI front-end connectors | Connection to a Fiber Channel fabric or iSCSI network |
Ethernet connectors | MGMT – 1 Gbps or 10 Gbps embedded Ethernet port used for Storage Center management |
SAS back-end connectors | 12 Gb SAS ports for connections to
expansion enclosures
NOTE SAS connectors are SFF-8644 compliant.
|
Serial connector (micro USB) | Used for initial configuration and support-only functions |
LED Indicators | |
---|---|
Front panel |
|
Hard drive carrier |
|
Storage controller |
|
Power supply/cooling fan | One dual-color LED handle indicating power supply and cooling fan status |
Power Supply Units (PSU) | PSU Type 1 | PSU Type 2 (Japan Only) |
---|---|---|
Maximum output power | 1485 W | 1485 W |
Maximum input power | 1688 W | 1707 W |
Maximum input current | 8.8 A | 17.5 A |
Maximum inrush current | 55 A for 10 ms or less | 55 A for 10 ms or less |
Nominal input voltage operating range | 200–240 VAC | 100–240 VAC |
Nominal input frequency | 50/60 Hz | 50/60 Hz |
Thermal output/heat dissipation | 693 BTU per hour | 757 BTU per hour |
Inlet type | C14 | C20 |
Available Hard Drive Power (Per Slot) | |
---|---|
Supported hard drive power consumption (continuous) | Up to 1.2 A at +5 V
Up to 0.5 A at +12 V |
Physical | |
---|---|
Height | 13.34 cm (5.25 in.) |
Width | 44.50 cm (17.5 in.) |
Depth | 78.27 cm (31 in.) |
Approximate weight (maximum configuration) | 45 kg (100 lb) |
Approximate weight without drives | 35 kg (77 lb) |
Environmental | |
---|---|
For additional information about environmental measurements for specific storage system configurations, see https://www.dell.com/environmental_datasheets. | |
Temperature | |
Operating | 10°C (50°F) to 35°C (95°F) with a maximum temperature gradation of 20°C/hour (36°F/hour)
Operating above 35°C could result in data loss |
Storage | –40° to 65°C (–40° to 149°F) at a maximum altitude of 12,000 m (39,370 ft) |
Relative humidity | |
Operating | 10% to 80% (noncondensing) with 29°C (84.2°F) maximum dew point |
Storage | 5% to 95% (noncondensing) with 33°C (91°F) maximum dew point |
Maximum vibration | |
Operating | 0.26 Grms at 5–350 Hz for 15 min |
Storage | 1.88 Grms at 10–500 Hz for 15 min |
Maximum shock | |
Operating | 31 G +/- 5% with pulse duration of 2.6 ms +/- 10% (equivalent to 20 in./sec [51 cm/sec]) |
Storage | 71 G +/- 5% with pulse duration of 2 ms +/- 10% (equivalent to 35 in./sec [89 cm/sec]) |
Altitude | |
Operating | 3,048 m (10,000 ft)
≤35°C (95°F) Maximum Rating – Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (3,117 ft) |
Storage | 12,000 m (39,370 ft) |
Airborne Contaminant Level | |