跳至主要內容
  • 簡單快速地下訂單
  • 檢視訂單及追蹤商品運送狀態
  • 建立並存取您的產品清單
  • 使用「公司管理」來管理您的 Dell EMC 網站、產品和產品層級連絡人。

Dell PowerEdge T360 Installation and Service Manual

Removing the BOSS-N1 card carrier

Prerequisites

  1. Follow the safety guidelines listed in Safety instructions.
  2. Follow the procedure that is listed in Before working inside your system.
  3. If installed, remove the front bezel.

Steps

  1. Open the release latch and slide the BOSS-N1 card carrier out of the BOSS-N1 module.
    Figure 1. Removing the BOSS-N1 card carrier
    This image shows the removal of the BOSS-N1 card carrier.
  2. Using the Phillips 1 screwdriver removes the M3 x 0.5 x 4.5 mm screw that secures the M.2 NVMe SSD to the BOSS-N1 card carrier.
  3. Slide the M.2 NVMe SSD out from the BOSS-N1 card carrier.
    Figure 2. Removing the M.2 NVMe SSD
    Removing the M.2 NVMe SSD
  4. If not installing the BOSS-N1 card carrier, align and push the BOSS-N1 card carrier blank into the BOSS-N1 module to fill the empty BOSS-N1 card carrier slot.
    Figure 3. Installing the BOSS-N1 card carrier blank
    This image shows the installation of the BOSS-N1 card carrier blank.

對此內容評分

準確
實用
易懂
這篇文章對您有用嗎?
0/3000 characters
  請給予評分 (1 到 5 顆星)。
  請給予評分 (1 到 5 顆星)。
  請給予評分 (1 到 5 顆星)。
  本文章是否有幫助?請選擇。
  評語中不得包含下列特殊字元:<>()\