Event ID — 2048

Description
Device failed.
Severity
Critical / Failure / Error
Cause and Action
Cause: A storage component such as a physical disk or an enclosure has failed. The failed component may have been identified by the controller while performing a task such as a rescan or a check consistency.

Action: Replace the failed component. You can identify which disk has failed by locating the disk that has a red “X” for its status. Perform a rescan after replacing the failed component.

Related Alert Information
Clear Alert Number: 2121

Related Alert Number: 2095, 2201, 2203

Local Response Agent (LRA) Number: 2051, 2061, 2071, 2081, 2091, 2101

SNMP Trap Numbers
754, 804, 854, 904, 954, 1004, 1054, 1104, 1154, 1204