跳至主要內容
  • 簡單快速地下訂單
  • 檢視訂單及追蹤商品運送狀態
  • 建立並存取您的產品清單
  • 使用「公司管理」來管理您的 Dell EMC 網站、產品和產品層級連絡人。

Server Administrator Version 7.4 Messages Reference Guide

PDF

Event ID — 2432

Description
The PCIeSSD device was found to be in security locked state. Full initialization has to be done on the security locked drive to recover the drive in usable state.
Severity
Warning
Cause and Action
Cause: Last full initialization was stopped for some reason and hence the device is in security locked state.

Action: Run full initialization to recover the device.

Related Alert Information
Clear Alert Number: None

Related Alert Number: None

Local Response Agent (LRA) Number: None

SNMP Trap Numbers
902

對此內容評分

準確
實用
易懂
這篇文章對您有用嗎?
0/3000 characters
  請給予評分 (1 到 5 顆星)。
  請給予評分 (1 到 5 顆星)。
  請給予評分 (1 到 5 顆星)。
  本文章是否有幫助?請選擇。
  評語中不得包含下列特殊字元:<>()\