跳至主要內容
  • 簡單快速地下訂單
  • 檢視訂單及追蹤商品運送狀態
  • 建立並存取您的產品清單
  • 使用「公司管理」來管理您的 Dell EMC 網站、產品和產品層級連絡人。

Server Administrator Version 7.4 Messages Reference Guide

PDF

Event ID — 2322

Description
The DC power supply is switched off.
Severity
Informational
Cause and Action
Cause: The power supply unit is switched off. Either a user switched off the power supply unit or it is defective.

Action: Check if the power switch is turned off. If it is turned off, turn it on. If the problem persists, check if the power cord is attached and functional. If the problem is still not corrected or if the power switch is already turned on, replace the power supply unit.

Related Alert Information
Clear Alert Number: 2323

Related Alert Number: None

Local Response Agent (LRA) Number: 2091

SNMP Trap Numbers
1001

對此內容評分

準確
實用
易懂
這篇文章對您有用嗎?
0/3000 characters
  請給予評分 (1 到 5 顆星)。
  請給予評分 (1 到 5 顆星)。
  請給予評分 (1 到 5 顆星)。
  本文章是否有幫助?請選擇。
  評語中不得包含下列特殊字元:<>()\