跳至主要內容
  • 簡單快速地下訂單
  • 檢視訂單及追蹤商品運送狀態
  • 建立並存取您的產品清單
  • 使用「公司管理」來管理您的 Dell EMC 網站、產品和產品層級連絡人。

Server Administrator Version 7.4 Messages Reference Guide

PDF

Event ID — 2057

Description
Virtual disk degraded.
Severity
Warning / Non-critical
Cause and Action
Cause 1: This alert message occurs when a physical disk included in a redundant virtual disk fails. Because the virtual disk is redundant (uses mirrored or parity information) and only one physical disk has failed, the virtual disk can be rebuilt.

Action 1: Replace the failed drive. Rebuild of the virtual disk starts automatically.

  • NOTE: If you put the drive in a different slot, you need to assign it as a hot spare for the rebuild to start automatically.

If you put the drive in a different slot, you need to assign it as a hot spare for the rebuild to start automatically.

Cause 2: A physical disk in the disk group has been removed.

Action 2: If a physical disk was removed from the disk group, either replace the disk or restore the original disk. You can identify which disk has been removed by locating the disk that has a red “ X” for its status. Perform a rescan after replacing the disk.

Related Alert Information
Clear Alert Number: None

Related Alert Number: 2048, 2049, 2050, 2076, 2079, 2081, 2123, 2129, 2346

Local Response Agent (LRA) Number : 2080

SNMP Trap Numbers
1203

對此內容評分

準確
實用
易懂
這篇文章對您有用嗎?
0/3000 characters
  請給予評分 (1 到 5 顆星)。
  請給予評分 (1 到 5 顆星)。
  請給予評分 (1 到 5 顆星)。
  本文章是否有幫助?請選擇。
  評語中不得包含下列特殊字元:<>()\