Server Administrator Version 7.4 Messages Reference Guide

PDF

Event ID — 2081

Description
Virtual disk reconfiguration failed.
Severity
Critical / Failure / Error
Cause and Action
Hardware RAID:

Cause: A physical disk included in the virtual disk has failed or is not functioning. A user may also have cancelled the reconfiguration.

Action: Replace the failed or non-functional disk. You can identify a disk that has failed by locating the disk that displays a red X in the status field.

If the physical disk is part of a redundant array, then rebuild the physical disk. When finished, restart the reconfiguration.

Software RAID:
  • Perform a backup with the Verify option.
  • If the file backup fails, try to restore the failed file from a previous backup.
  • When the backup with the Verify option is complete without any errors, delete the Virtual Disk.
  • Recreate a new Virtual Disk with new drives.
  • Restore the data from backup.
Related Alert Information
Clear Alert Number: None

Related Alert Number: None

Local Response Agent (LRA) Number: 2081

SNMP Trap Numbers
1204