跳至主要內容
  • 簡單快速地下訂單
  • 檢視訂單及追蹤商品運送狀態
  • 建立並存取您的產品清單
  • 使用「公司管理」來管理您的 Dell EMC 網站、產品和產品層級連絡人。

Server Administrator Version 7.4 Messages Reference Guide

PDF

Event ID — 2417

Description
There is an unrecoverable medium error detected on virtual disk.
Severity
Critical / Failure / Error
Cause and Action
Cause: Unrecoverable medium error found on one or more member physical disks of a virtual disk.

Action: Perform a backup of the virtual disk with the Verify option selected. If the Backup operation is successful, it indicates that the un-recoverable medium did not affect user data.

If the Backup operation fails, restore the file from a previous backup. After restoring the file, run check consistency operation:
  • If the consistency check is successful, no further action is required.
  • If the consistency check finds and unrecoverable medium error, it means that the medium error is located in non-user data. No further action is required as, writing data to the location of the medium error fixes the problem.
  • NOTE: If the unrecoverable medium error has not been corrected, it may be reported again by the system. This error can be fixed by writing data on the affected area or deleting and recreating the Virtual Disk as demonstrated in the following procedure.
    1. Back up the data.
    2. Delete the Virtual Disk.
    3. Recreate the Virtual Disk using the same parameters like size, RAID level, disks, etc.
    4. Restore data.