Server Administrator Version 7.4 Messages Reference Guide

PDF

Event ID — 2206

Description
The only hot spare available is a SATA disk. SATA disks cannot replace SAS disks.
Severity
Warning / Non-critical
Cause and Action
Cause: The only physical disk available to be assigned as a hot spare is using SATA technology. The physical disks in the virtual disk are using SAS technology. Because of this difference in technology, the hot spare cannot rebuild data if one of the physical disks in the virtual disk fails.

Action: Add a SAS disk that is large enough to be used as the hot spare and assign it as a hot spare.

Related Alert Information
Clear Alert Number: None

Related Alert Number: None

Local Response Agent (LRA) Number: 2070

SNMP Trap Numbers
903