PowerStore Alerts: Internal M.2 Disk Alerts

Summary: This article discusses Internal M.2 Disk Alerts.

This article may have been automatically translated. If you have any feedback regarding its quality, please let us know using the form at the bottom of this page.

Article Content


Symptoms

When Dell PowerStore encounters an issue, an error alert is generated to help identify the issue. This article explains the different possible causes and the relevant remediation for these error alerts. If your issue is not resolved despite the solution provided, check the technical support contact options.
SLN317231_en_US__1icon Note: Can't find the information you need? Let us know via the feedback form at the bottom of this article.

Cause

Cause is mentioned in the Resolution section under respective alerts.

Resolution

Alert ID XMS_LOCAL_DISK_DISK_FAILURE_EMPTY
Alert Text Internal M.2 boot module slot in %(slot_num) used as %(local_disk_purpose) is empty.
Error Code (0x00305602)
Resolution Cause
This alert is raised when an Internal M.2 Boot Module is not detected at initial installation.

Remediation
Two M.2 Boot Modules, internal to each node, are required. Contact technical support to replace the missing Internal M.2 Boot Module .
 
 
Alert ID XMS_LOCAL_DISK_FRU_STATE_DISCONNECTED
Alert Text Internal M.2 boot module is disconnected.
Error Code (0x00305804)
Resolution Cause
The Internal M.2 Boot Module is not detected or the SN/PN cannot be retrieved. One of the following may cause this condition:      
  1. The Internal M.2 Boot Module is physically disconnected or removed.
  2. As the result of the replacement of a M.2 Boot Module or of an adjacent DIMM, the M.2 Boot Module may not be properly seated.
  3. The Internal M.2 Boot Module is not visible to the platform software.
Remediation
 
 
Alert ID XMS_LOCAL_DISK_FRU_COMP_STATUS_INCOMPATIBLE
Alert Text Internal M.2 boot module in slot %(slot_num)s of size %(size_gb)s GB does not meet the minimum required size of %(min_size_gb)s GB for this slot.
Error Code (0x0030b702)
Resolution Cause
This alert is raised if the Internal M.2 Boot Module is replaced with a non-compatible device.

Remediation
Replace the affected Internal M.2 Boot Module with a compatible part.
 
 
Alert ID XMS_LOCAL_DISK_FRU_STATE_FAILED
XMS_LOCAL_DISK_POLLING_STATUS_FAILED
XMS_LOCAL_DISK_POLLING_STATUS_CRITICAL
Alert Text Internal M.2 boot module has faulted.
Polling failed for internal M.2 boot module in slot %(slot_num)s.
Root file system is read-only on internal M.2 boot module in slot %(slot_num)s.
Error Code (0x00305803)
(0x0030ba02)
(0x0030ba03)
Resolution Cause
  1. (0x00305803) is generated when the M.2 device SMART status indicates there is an issue with the device.
  2. (0x0030ba03) is raised when the root file system on the Module 0 M.2 boot module becomes read-only. This condition also causes the node to fail, raising the alert (0x00305803) because the system cannot operate with the device in this state.
  3. (0x0030ba02) is raised due to a system monitoring error in polling the state of the device. This condition may also raise  (0x00305803).
Remediation