Symptoms
When Dell PowerStore encounters an issue, an error alert is generated to help identify the issue. This article explains the different possible causes and the relevant remediation for these error alerts. If your issue is not resolved despite the solution provided, contact Dell Technical Support.
Note: Cannot find the information you need? Let us know using the feedback form at the bottom of this article.
Cause
The cause is mentioned in the Resolution section under the respective alerts.
Resolution
| Alert ID | XMS_LOCAL_DISK_DISK_FAILURE_EMPTY |
| Alert Text | The internal M.2 boot module slot in %(slot_num) used as %(local_disk_purpose) is empty. |
| Error Code | (0x00305602) |
| Resolution | Cause This alert is raised when an Internal M.2 Boot Module is not detected at initial installation. Remediation Two M.2 Boot Modules, internal to each node, are required. Contact Dell Technical Support to replace the missing Internal M.2 Boot Module. |
| Alert ID | XMS_LOCAL_DISK_DISK_FAILURE_UNINITIALIZED |
| Alert Text | The internal M.2 boot module is not initialized. |
| Error Code | (0x00305606) |
| Resolution | Cause This alert is raised when an Internal M.2 Boot Module is not initialized. Remediation If the issue persists, contact Dell Technical Support. |
| Alert ID | XMS_LOCAL_DISK_FRU_STATE_DISCONNECTED |
| Alert Text | The internal M.2 boot module is disconnected. |
| Error Code | (0x00305804) |
| Resolution | Cause The Internal M.2 Boot Module is not detected or the SN/PN cannot be retrieved. One of the following may cause this condition:
|
| Alert ID | XMS_LOCAL_DISK_FRU_COMP_STATUS_INCOMPATIBLE |
| Alert Text | Internal M.2 boot module in slot %(slot_num)s of size %(size_gb)s GB does not meet the minimum required size of %(min_size_gb)s GB for this slot. |
| Error Code | (0x0030b702) |
| Resolution | Cause This alert is raised if the Internal M.2 Boot Module is replaced with a non-compatible device. Remediation Replace the affected Internal M.2 Boot Module with a compatible part. |
| Alert ID | XMS_LOCAL_DISK_FRU_STATE_FAILEDXMS_LOCAL_DISK_POLLING_STATUS_FAILEDXMS_LOCAL_DISK_POLLING_STATUS_CRITICAL |
| Alert Text | The internal M.2 boot module has faulted.Polling failed for internal M.2 boot module in slot %(slot_num)s.Root file system is read-only on the internal M.2 boot module in slot %(slot_num)s. |
| Error Code | (0x00305803)(0x0030ba02)(0x0030ba03) |
| Resolution | Cause
|