PowerVault ML3 机械手由于装运锁而初始化失败

Summary: 如果装运锁未正确找到,PowerVault ML3 将无法初始化。 这会导致系统无法启动事件 2065 或事件 2097。

This article may have been automatically translated. If you have any feedback regarding its quality, please let us know using the form at the bottom of this page.

Article Content


Symptoms

客户可能会注意到,ML3 最初无法初始化并显示“机器人初始化失败”消息。机械手确实在机箱中移动并扫描一些插槽,但它无法扫描任一磁带盒中的正面插槽。

如果运输锁在锁和解锁位置之间浮动,则机械手无法完成初始化的移动。有时,机械手会扫描机箱的左侧和右侧,但无法扫描左侧或右侧磁带盒中的正面插槽。

从库 ticketlog.txt:

Event 2065 - Library startup process failed because of robotics initialization issue.

Event 2097 - Mechanical reinitialization in the context of Robotics error recovery has failed.

Cause

浮动运输锁。

Resolution

重新定位运输锁。

要解决此问题,操作员应:
  1. 关闭 ML3 电源
  2. 轻轻地将机械手提离运输锁。 
  3. 将运输锁上的拉杆移至“解锁”位置。 
  4. 完成后,打开 ML3 电源

图 1.蓝色拉杆运输锁的位置不正确,不允许机械手完成移动。

蓝色运输锁杆处于不正确的位置


图 2.蓝色拉杆传送锁处于正确的位置,允许机械手移动。

蓝色运输锁杆处于正确的位置


图 3.蓝色拉杆传送锁已锁定。

蓝色运输锁杆已锁定


图 4.蓝色拉杆传送锁已解锁。

蓝色运输锁拉杆已解锁