Upgrading Unisphere for PowerMax fails because SMAS DB stops and won't start

Summary: Upgrading Unisphere for PowerMax fails because SMAS DB stops and won't start.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Instructions

Customer experienced and issue when upgrading Unisphere for PowerMax on a standalone Windows Server 2019 due to the SMAS DB service being stopped and won't start. Manual attempts to start SMAS DB from Windows Management Console failed.


Evidence in logs:
<hostname>_APPLICATION_EVENTLOG.TXT
08/18/2022 12:25:41 PM  Error         <hostname> 0       PostgreSQL                       {2022-08-18 19:25:41 GMT::@:[1668]:FATAL:  lock file "postmaster.pid" already exists 2022-08-18 19:25:41 GMT::@:[1668]:HINT:  Is another postmaster (PID XXXX) running in data directory "C:/Program Files/EMC/SMAS/jboss/standalone/data/pgsql/data"? }


Moved both postmaster.opts and postmaster.pid from C:/Program Files/EMC/SMAS/jboss/standalone/data/pgsql/data to a different folder. 

Both files appear to be tied together as they were both generated at the same time on each attempt to manually start SMAS DB.

Stopped SMAS and ensured SMAS DB was not running.
Started SMAS DB, and started SMAS services and both were successful.

postmaster.opts and postmaster.pid were rebuilt after the SMAS DB and SMAS services were started and proceeded with upgrade of Unisphere for PowerMax which was successful.

Additional Information

postmaster.pid is the pidfile written by the postmaster process. As well as the postmaster's PID, it contains additional information about the running instance.

postmaster.opts is a file in the data directory written after startup which contains the options used to start the postmaster process. The contents of postmaster.opts are used to ensure the postmaster process can be restarted with the same options with which it was originally started.

Affected Products

Unisphere for PowerMax
Article Properties