Unisphere for PowerMax:遠端 Syslog 組態失敗,並顯示錯誤訊息「java.net.SocketException:Connection reset」
Summary: 遠端 syslog 組態失敗,並顯示錯誤「java.net.SocketException:連線已重設。」
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
嘗試從>設定安全性>遠端系統記錄為 PowerMax 的 Unisphere 設定遠端系統記錄時,失敗並顯示錯誤:
smas.log只有下列項目:
java.net.SocketException: Connection reset
圖 1:Error:
java.net.SocketException:連線重設
smas.log只有下列項目:
2022-03-04 14:49:11,568 ERROR [em.bp.SECURITY] (default task-40) SecurityCommandProcessor.processConfigureRemoteSyslogCommand:java.net.SocketException: Connection reset 2022-03-04 14:51:39,978 ERROR [em.bp.SECURITY] (default task-14) SecurityCommandProcessor.processConfigureRemoteSyslogCommand:java.net.SocketException: Connection reset 2022-03-07 15:50:51,998 ERROR [em.bp.SECURITY] (default task-31) SecurityCommandProcessor.processConfigureRemoteSyslogCommand:java.net.SocketException: Connection reset
Cause
此錯誤是由於網路問題所導致。
Resolution
使用者的網路團隊發現埠 6514 的流量已受阻。網路問題解決後,他們即可設定遠端 syslog。