Cisco: Interface and command code info missing from %FCNS-3-BAD_FRAME syslog message
Summary: Interface and command code information missing from %FCNS-3-BAD_FRAME syslog message
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
The syslog error message missing the interface where the command came from and it is missing the command code that was invalid.
%FCNS-3-BAD_FRAME: %$VSAN 99%$ : Invalid CT command code
Found in code NX-OS 8.1.1
Source interface is also missing for the error message in show fcns internal errors:
...
8) Event:E_DEBUG, length:94, at 651075 usecs after Wed Nov 20 10:58:26 2019
[825307441] ns_handle_command(6273): vsan:20 FC2: Received a frame with invalid CT command code 1801
9) Event:E_DEBUG, length:94, at 647947 usecs after Wed Nov 20 10:58:26 2019
[825307441] ns_handle_command(6273): vsan:20 FC2: Received a frame with invalid CT command code 3901Cause
Cisco bug - CSCvs19448
This occurs when the attached device sends in an invalid FCNS command.
Resolution
The syslog has been modified to include the invalid command code, the FCID, and the interface as follows: switchname %FCNS-3-BAD_FRAME: %$VSAN 1%$ : Invalid CT command code[0xfef7] from device[0xea0000], interface[fc1/14]
A similar change was done to the message in show fcns internal errors.
Fix:
Upgrade to NX-OS 8.42 and higher
Affected Products
Connectrix MDS-Series Firmware 8.XArticle Properties
Article Number: 000220758
Article Type: Solution
Last Modified: 23 Feb 2026
Version: 3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.