Symptoms
From the SRM Recovery Report, the errors are highlighted as below:
Failed to recover datastore 'xxxxxxxx'. VMFS volume residing on recovered devices '"a2d686f3-54ca-4db4-ae21-1ab7f156187a". Recovered device 'a2d686f3-54ca-4db4-ae21-1ab7f156187a' not found after HBA rescan
Cause
- SRM failover test creates a snapshot on the DR PowerStore and maps the snapshot to the DR ESXi hosts with the PowerStore automatically generated Host LUN ID (HLU).
- The PowerStore automatically generated HLU uses N+1 (where N=highest HLU) logic to enumerate LUN IDs (HLU) up to a max HLU 16383 for ESXi.
- Esxi max HLU =1024 by default
- If there are many LUNs protected by SRM and multiple failover tests were performed in the past months, the new mapping HLU could reach to 1024+ which results in the ESXi hosts cannot discover the device mapping on the DR ESXi. This may also affect other applications which automatically map snapshots, see PowerStore: Volumes Mapped Through REST API By an Application Are Not Visible on ESXi
Resolution
Increase the Disk.MaxLUN to 16383 on all VMware ESXi hosts in the cluster
https://docs.vmware.com/en/VMware-vSphere/7.0/com.vmware.vsphere.storage.doc/GUID-22710463-E035-4EB9-8FB1-CA12731D43CA.html
Affected Products
SRM, PowerStoreOSArticle Properties
Article Number: 000223787
Article Type: Solution
Last Modified: 17 May 2024
Version: 3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.