Two symptoms are seen:
- The scheduled or manual discovery job for the storage array fails.
- The problematic storage array's volume or volume group cannot be shown as the target one while doing restore.
discovery-service.log: 2023-10-30T04:48:24.039Z ERROR [] [604c5853-8a26-4c6c-9e6c-3901bcbc0c64-akka.actor.default-dispatcher-5] [][][SUB_TASK_ID:aad2f7aa2ab0f9e9][TRACE_ID:927ed764cfef3843;JOB_ID:811ce7d1084f6791][] [c.e.b.d.a.p.a.PowerStoreApplianceActor.updateDataSourceResouce(317)] - Error during Error parsing response - {}
com.emc.brs.discovery.adapters.powerStore.util.PowerStoreDiscoveryException: Internal Error: unable to parse json.Oorzaak
It is a parsing error.
SDMNG discovery model is not having a Fractured ENUM because of which parsing error appears.
SDMNG discovery model is not having a Fractured ENUM because of which parsing error appears.
Oplossing
This issue is addressed in version 19.15.