NOTE: Your storage enclosure
is shipped with two IEC C19 to C20 jumper cords. Connect the C19 plug
to the enclosure’s power supplies and the C20 plug to the power distribution
unit (PDU) in the rack cabinet.
Figure 1. Power Supply
Module Features and Status Indicators
Item
Indicator or Connector
Icon
Description
1
Power connector
Connect the external power supply source
to this connector.
2
Power switch
The power switch controls the power supply
output to the system.
3
Standby power indicator
The standby power indicator lights green
when the system is in standby mode and the main power is off.
4
DC power indicator
Green
Indicates that DC output voltage is within the limit.
Off
Indicates that DC output voltage is not within the limit.
5
Service action allowed indicator
CAUTION: Remove
the power supply module from the system only if the Service action
allowed indicator lights blue. Removing the power supply module from
the system when the Service action allowed indicator is off may damage
the system.
NOTE: The Service action allowed indicator LED is not used in server attached
configurations.
Blue
Indicates that you can safely remove the power supply module from
the system.
Off
Indicates that you cannot remove the power supply module from
the system.
6
Service action required indicator
The service action required indicator
lights amber when there is a fault in the power supply module.
7
AC power indicator
Green
Indicates that AC output voltage is within the limit.
Off
Indicates that AC output voltage is not within the limit.