CAUTION: Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized
in your product documentation, or as directed by the online or telephone
service and support team. Damage due to servicing that is not authorized
by Dell is not covered by your warranty. Read and follow the safety
instructions that came with the product.
CAUTION: The
cooling fans are hot-swappable. To maintain proper cooling while the
system is on, replace only one fan at a time.
NOTE: The procedure for removing
each cooling fan module is identical.
Make sure that the
Service action allowed indicator lights blue before you remove
the cooling fan module. For more information, see
Cooling Fan Module
LED Indicator Codes
.
NOTE: The Service action
allowed indicator LED is not used in server attached configurations.
Identify and locate the failed cooling fan module.
CAUTION: Remove the cooling fan module from the system only
if the Service action allowed indicator lights blue. Removing the
cooling fan module from the system when the Service action allowed
indicator is off may damage the system.
NOTE: The Service
action allowed indicator LED is not used in server attached configurations.
Press the cooling fan module release latch to release the
cooling fan module handle.
Rotate the cooling fan module handle away from the system,
until the cooling fan module is released from the slot.
Holding the cooling fan module release handle, pull the
cooling fan module away from the chassis.
Figure 1. Removing and
Installing the Cooling Fan Module
cooling fan module release latch
cooling fan module handle
cooling fan module