Configuring Power Factor Correction (PFC) for power supplies in all 15
th generation of PowerEdge systems is not supported.
While BIOS is set to Boot mode, boot capture video file size is limited to 2 MB. During the video capture, if the size of video file exceeds the limit, then only partial operation is captured.
CPLD update may fail if DUP method is used while power cap policy is enabled.
Remote File Share (RFS) through HTTP is only supported without authentication.
If part replacement is performed on systems with two PSUs while upgrade option is enabled, then the firmware update for both the PSUs are repeated once.
IPMItool interface does not report noncommunicative PSU status for PowerEdge Rx4xx/Cx4xx servers.
Arrow keys on virtual keyboard of the iDRAC Virtual Console with eHTML5 plug-in do not respond inside BIOS boot manager after the system reboots. Close and reopen the eHTML5 Virtual console session.
If SOL session is active for a long duration or if the system is rebooted multiple times, the SOL session gets terminated automatically.
For Dell online catalog update, downloads.dell.com only supports https protocol.
If you install OMSA while iSM is already installed and connected, iSM may restart after the OMSA installation is complete.
In SLES and RHEL, the native video players do not support the MPEG-1 video formats. To play the captured videos, install an MPEG decoder or a video player that supports this format.