SMART error detected on a physical disk in a redundant virtual disk

Issue:
A SMART error is detected on a physical disk in a redundant virtual disk.
Corrective Action:
Perform the following steps:
  1. Back up your data.
  2. Force the physical disk offline.
    NOTE:If a hot-spare is present, the rebuild starts with the hot-spare after the disk is forced offline.
  3. Replace the disk with a new physical disk of equal or higher capacity.
  4. Perform the Replace Member operation.
    NOTE:The Replace Member operation allows you to copy data from a source physical disk of a virtual disk to a target physical disk that is not a part of the virtual disk. For more information about the Replace Member feature, see Configure hot-spare drives.