Dell PowerVault ME5 Series Administrator's Guide

Update expansion-module and drawer firmware

Perform the following steps to update the expansion-module and drawer firmware:

Steps

  1. As a user with a manage role, obtain the appropriate firmware file, and download it to your computer or network.
  2. If you want to update all expansion modules, go to the next step. Otherwise, in the PowerVault Manager, determine the address of each expansion module to update:
    1. In the Maintenance > Hardware panel, select a drive enclosure.
    2. In the enclosure device details pane, note each EMP bus ID and target ID values. For example, 0 and 63, and 1 and 63. Bus 0 is the bus that is native to a given controller, while bus 1 is an alternate path through the partner controller. Dell recommends performing update tasks consistently through one controller to avoid confusion.
  3. In the PowerVault Manager (Settings > Network > Services panel), prepare to use FTP:
    1. Determine the network-port IP addresses of the system’s controllers.
    2. Verify that the FTP service is enabled on the system.
    3. Verify that the user you will log in as has permission to use the FTP interface. If the system has a single controller, stop I/O to disk groups before starting the firmware update.
  4. Open a Command Prompt (Windows) or a terminal window (UNIX) and go to the directory containing the firmware file to load.
  5. Enter:
    sftp -P<port controller-network-address> or ftp <controller-network-address>
    For example:

    sftp -P 1022 10.235.216.152 or

    ftp 10.1.0.9

  6. Log in as an FTP user.
  7. Make sure the client is in binary transfer mode. Enter:
    binary
  8. Perform either of the following tasks:
    • To update all expansion modules, type:

      put <firmware-file> encl

    • To update specific expansion modules, type:

      put <firmware-file> encl:<EMP-bus-ID>:<EMP-target-ID>

    CAUTION Do not perform a power cycle or controller restart during the firmware update. If the update is interrupted or there is a power failure, the module might become inoperative. If this issue occurs, contact technical support. The module might need to be returned to the factory for reprogramming.

    It typically takes 2.5 minutes to update each EMP in a drive enclosure. Wait for a message that the code load has completed.

    NOTE If the update fails, verify that you specified the correct firmware file and try the update a second time. If it fails again, contact technical support.
  9. If you are updating specific expansion modules, repeat step 8 for each remaining expansion module that needs to be updated.
  10. Quit the FTP session.
  11. Verify that each updated expansion module has the correct firmware version.