Unisphere and Unisphere Central 2020 R1 Administrator's Guide

Add a VLAN ID to a Physical iSCSI Fault Domain

Add a VLAN ID to an existing iSCSI fault domain if the ports in the fault domain are connected to a tagged network.

Prerequisites

The Storage Center iSCSI ports must be configured for virtual port mode.

Steps

  1. If you are connected to a Data Collector, select a Storage Center from the drop-down list in the left navigation pane of Unisphere Central.
  2. From the System iconSYSTEM menu, click Ports.
    The Ports view is displayed.
  3. Click the Front End Ports tab.
  4. Expand iSCSI and click the fault domain link.
    The Fault Domain view is displayed.
  5. On the Summary tab, click Edit icon(Edit).
    The Edit iSCSI Fault Domain dialog box opens.
  6. Select the VLAN Tagged checkbox.
  7. In the VLAN ID field, type a VLAN ID for the fault domain. Allowed values are 1–4096.
  8. (Optional) To assign a priority level to the VLAN, type a value from 0-7 in the Class of Service Priority field. 0 is best effort, 1 is the lowest priority, and 7 is the highest priority.
  9. Click OK.