Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell PowerEdge FN I/O Module Command Line Reference Guide 9.10(0.0)

PDF

show ip interface

View IP-related information on all interfaces.

Syntax show ip interface [ interface | brief] [configuration]
Parameters
interface (OPTIONAL) Enter the following keywords and slot/port or number information:
  • For the Management interface, enter the keyword ManagementEthernet followed by zero (0).
  • For a Port Channel interface, enter the keywords port-channel followed by a number. The range is from 1 to 128.
  • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet followed by the slot/port information.
  • For a VLAN, enter the keyword vlan followed by a number from 1 to 4094.
brief (OPTIONAL) Enter the keyword brief to view a brief summary of the interfaces and whether an IP address is assigned.
configuration (OPTIONAL) Enter the keyword configuration to display the physical interfaces with non-default configurations only.
Command Modes
  • EXEC
  • EXEC Privilege
Supported Modes All Modes
Command History
Version Description
9.4(0.0) Supported on the FN I/O Aggregator.
8.3.17.0 Supported on the M I/O Aggregator.
Usage Information The following describes the show ip interface command shown in the following example.
Lines Description
TenGigabitEthernet 0/0... Displays the interface’s type, slot/port and physical and line protocol
Internet address... States whether an IP address is assigned to the interface. If one is, that address is displayed.
IP MTU is... Displays IP MTU value.
Inbound access... Displays the name of the any configured incoming access list. If none is configured, the phrase “not set” is displayed.
Proxy ARP... States whether proxy ARP is enabled on the interface.
Split horizon... States whether split horizon for RIP is enabled on the interface.
Poison Reverse... States whether poison for RIP is enabled on the interface
ICMP redirects... States if ICMP redirects are sent.
ICMP unreachables... States if ICMP unreachable messages are sent.
Example
Dell#show ip int te 0/0
                                             TenGigabitEthernet 0/0 is down, line protocol is down
                                             Internet address is not set
                                             IP MTU is 1500 bytes
                                             Inbound access list is not set
                                             Proxy ARP is enabled
                                             Split Horizon is enabled
                                             Poison Reverse is disabled
                                             ICMP redirects are not sent
                                             ICMP unreachables are not sent
                                             Dell#
                                          
Usage Information The following describes the show ip interface brief command shown in the following example.
Fields Description
Interface Displays type of interface and the associated slot and port number.
IP-Address Displays the IP address for the interface, if configured.
Ok? Indicates if the hardware is functioning properly.
Method Displays “Manual” if the configuration is read from the saved configuration.
Status States whether the interface is enabled (up) or disabled (administratively down).
Protocol States whether IP is enabled (up) or disabled (down) on the interface.
Example (Brief)
Dell#show ip int brief
                                             Interface             IP-Address  OK? Method Status Protocol
                                             TenGigabitEthernet 0/1 unassigned NO  None   up      down
                                             TenGigabitEthernet 0/2 unassigned YES None   up      up
                                             TenGigabitEthernet 0/3 unassigned YES None   up      up
                                             TenGigabitEthernet 0/4 unassigned NO  None   up     down
                                             TenGigabitEthernet 0/5 unassigned NO  None   up     down
                                             TenGigabitEthernet 0/6 unassigned NO  None   up     down
                                             TenGigabitEthernet 0/7 unassigned NO  None   up     down
                                             TenGigabitEthernet 0/8 unassigned NO  None   up     down
                                             TenGigabitEthernet 0/9 unassigned NO  None   up     down
                                          

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\