Dell EMC PowerEdge RAID Controller S130 User’s Guide

Background Initialization

BGI of a redundant virtual disk creates the parity data that allows the virtual disk to maintain its redundant data and survive a physical disk failure. Similar to consistency check (CC), BGI helps the controller to identify and correct problems that might occur with the redundant data at a later time.

CAUTION: Data is lost if a physical disk fails before the completion of a BGI.

BGI allows a redundant virtual disk to be used immediately.

NOTE: Although a BGI is software-initiated at the BIOS Configuration Utility (<Ctrl><R>), the PERC S130 drivers must be loaded before the BGI runs.