Treceți la conținutul principal
  • Plasaţi comenzi rapid şi simplu
  • Vizualizaţi comenzile şi urmăriţi starea transportului
  • Creaţi şi accesaţi o listă cu produsele dvs.
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell PowerEdge FN I/O Module Configuration Guide 9.10(0.0)

PDF

Change the IS-IS Metric Style in One Level Only

By default, the IS-IS metric style is narrow. When you change from one IS-IS metric style to another, the IS-IS metric value (configured with the isis metric command) could be affected.

In the following scenarios, the IS-type is either Level-1 or Level-2 or Level-1-2 and the metric style changes.
Table 1. Metric Value When the Metric Style Changes
Beginning Metric Style Final Metric Style Resulting IS-IS Metric Value
wide narrow default value (10) if the original value is greater than 63. A message is sent to the console.
wide transition truncated value (the truncated value appears in the LSP only). The original isis metric value is displayed in the show config and show running-config commands and is used if you change back to transition metric style.
  • NOTE: A truncated value is a value that is higher than 63, but set back to 63 because the higher value is not supported.
wide narrow transition default value (10) if the original value is greater than 63. A message is sent to the console.
wide wide transition original value
narrow wide original value
narrow transition original value
narrow narrow transition original value
narrow wide transition original value
transition wide original value
transition narrow original value
transition narrow original value
transition wide transition original value
narrow transition wide original value
narrow transition narrow original value
narrow transition wide transition original value
narrow transition transition original value
wide transition wide original value
wide transition narrow default value (10) if the original value is greater than 63. A message is sent to the console.
wide transition narrow transition default value (10) if the original value is greater than 63. A message is sent to the console.
wide transition transition truncated value (the truncated value appears in the LSP only). The original isis metric value is displayed in the show config and show running-config commands and is used if you change back to transition metric style.

Moving to transition and then to another metric style produces different results.

Table 2. Metric Value when the Metric Style Changes Multiple Times
Beginning Metric Style Next Metric Style Resulting Metric Value Next Metric Style Final Metric Value
wide transition truncated value wide original value is recovered
wide transition transition truncated value wide transition original value is recovered
wide transition truncated value narrow default value (10). A message is sent to the logging buffer
wide transition transition truncated value narrow transition default value (10). A message is sent to the logging buffer