Passer au contenu principal
  • Passer des commandes rapidement et facilement
  • Afficher les commandes et suivre l’état de votre expédition
  • Créez et accédez à une liste de vos produits
  • Gérer vos sites, vos produits et vos contacts au niveau des produits Dell EMC à l’aide de la rubrique Gestion des informations de l’entreprise.

Dell Chassis Management Controller Version 3.0 for PowerEdge VRTX RACADM CLI Guide

PDF

get enclosure

Description

Displays the status and attributes of the enclosure.
NOTE To use this subcommand, you must have the CMC Login User privilege.

Synopsis

racadm raid get enclosures -o -p Status
racadm raid get enclosures -o

Input

  • -o — The -o is used to display the fault-tolerant status of a enclosure.
  • -p — The network password of the share.

Example

racadm raid get enclosures -o -p Status
Enclosure.Internal.0-0:RAID.ChassisIntegrated.2-1
Status = Ok
Enclosure.External.0-1:RAID.ChassisSlot.5-1
Status = Ok
Enclosure.External.0-0:RAID.ChassisSlot.5-1
Status = Failed
racadm raid get enclosures -o
Enclosure.Internal.0-0:RAID.ChassisIntegrated.2-1
 Status                           = Ok
   RollupStatus                   = Ok
   Name                           = VRTX2.5x25 0:0
   BayId                          = 0
   FirmwareVersion                = 2.00
   AssetTag                       = elan3
   AssetName                      = VRTX200   ternal backplane
   SasAddress                     = Not applicable
   SlotCount                      = 25
Enclosure.External.0-1:RAID.ChassisSlot.5-1
   Status                           = Ok
   RollupStatus                     = Ok
   Name                             = MD1220 0:1
   EnclosurePosition                = 1
   ConnectedPort                    = 0
   FirmwareVersion                  = 1.05
   ServiceTag                       = 6Q2XMQ1
   AssetTag                         = slot 5 1
   AssetName                        = MD1220
   RedundantPath                    = Present
   SasAddress                       = Not applicable
   SlotCount                        = 24
Enclosure.External.0-0:RAID.ChassisSlot.5-1
   Status                           = Failed
   RollupStatus                     = Failed
   Name                             = MD1220 0:0
   EnclosurePosition                = 0
   ConnectedPort                    = 0
   FirmwareVersion                  = 1.05
   ServiceTag                       = BWQPWP1
   AssetTag                         = slot 5 0
   AssetName                        = MD1220
   RedundantPath                    = Present
   SasAddress                       = Not applicable
   SlotCount                        = 24

Évaluez ce contenu

Précis
Utile
Facile à comprendre
Avez-vous trouvé cet article utile ?
0/3000 characters
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez indiquer si l’article a été utile ou non.
  Les commentaires ne doivent pas contenir les caractères spéciaux : <>()\