getniccfg

Table 1. getniccfgThe following table contains the description, synopsis, and input of the getniccfg command.

Description

Displays the current NIC settings.

Synopsis

racadm getniccfg

Input

racadm getniccfg
racadm getniccfg –m <module>

where –m must be one of the following values:

  • chassis  
    : default state if -m is not specified
  •  server-n 
    : where n = 1 to 4
  • switch-n 
    : where n = 1

Example

racadm getniccfg
NIC Enabled               = 1
IPv4 Enabled              = 1
DHCP Enabled              = 1
Static IP Address         = 192.168.0.120
Static Subnet Mask        = 255.255.255.0
Static Gateway            = 192.168.0.1
Current IP Address        = 10.94.225.212
Current Subnet Mask       = 255.255.255.128
Current Gateway           = 10.94.225.129
IPv6 Enabled              = 0
Autoconfiguration Enabled = 1
Static IPv6 Address       = ::/64
Static IPv6 Gateway       = ::
Link Local Address        = ::
Current IPv6 Address 1    = ::
Current IPv6 Gateway      = ::
Speed                     = Autonegotiate
Duplex                    = Autonegotiate
VLAN Enable               = 0
VLAN ID                   = 1
VLAN priority             = 0
racadm getniccfg -m server-3
LOM Model Name            = BRCM GbE 4P 5720 bNDC
LOM Fabric Type           = Gigabit Ethernet
IPv4 Enabled              = 1
DHCP Enabled              = 0
IP Address                = 0.0.0.0
Subnet Mask               = 0.0.0.0
Gateway                   = 0.0.0.0
IPv6 Enabled              = 0
Autoconfiguration Enabled = 1
Link local Address        =
IPv6 Gateway              = ::
VLAN Enable               = 0
VLAN ID                   = 1
VLAN priority             = 0
racadm getniccfg -m switch-1
DHCP Enabled              = 0
IP Address                = 0.0.0.0
Subnet Mask               = 0.0.0.0
Gateway                   = 0.0.0.0

Évaluez ce contenu

Précis
Utile
Facile à comprendre
Avez-vous trouvé cet article utile ?
0/3000 characters
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez indiquer si l’article a été utile ou non.
  Les commentaires ne doivent pas contenir les caractères spéciaux : <>()\