Connectrix: Cisco MDS: Module reset System Error code 0x42b8001e fatal error.

Summary: The issue is seen where the module resets and a few ports goes into "hw_Failure" state. The specific port range identified should be put into Hardware Failure state, but instead of the entire module being reloaded. The error "F16_PLDA_RETRY_MERR" is a multibit ECC error, uncorrectable hardware failure. ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

The specific port range goes into "hw_Failure" state:

`show interface brief`
-----------------------------------------------------------------------------------------
Interface  Vsan   Admin  Admin   Status       SFP    Oper  Oper   Port     Logical
                  Mode   Trunk                       Mode  Speed  Channel   Type
                         Mode                              (Gbps)
-----------------------------------------------------------------------------------------
fc9/41      1400   FX     off     hwFailure    swl   --     --     --       --       
fc9/42      1400   FX     off     hwFailure    swl   --     --     --       --       
fc9/43      1400   FX     off     hwFailure    swl   --     --     --       --       
fc9/44      1400   FX     off     hwFailure    swl   --     --     --       --       
fc9/45      1      FX     off     hwFailure    swl   --     --     --       --       
fc9/46      1      FX     off     hwFailure    swl   --     --     --       --       
fc9/47      1400   FX     off     hwFailure    swl   --     --     --       --       
fc9/48      1      E      on      hwFailure    swl   --     --     57       --    

The error code is seen in the module internal exception log as below:

`show module internal exceptionlog module 9`
********* Exception info for module 9 ********
exception information --- exception instance 1 ----
Module Slot Number: 9
Device Id         : 204
Device Name       : F16 Generic Driver
Device Errorcode  : 0xccc05600
Device ID         : 204 (0xcc)
Device Instance   : 05 (0x05)
Dev Type (HW/SW)  : 06 (0x06)
ErrNum (devInfo)  : 00 (0x00)
System Errorcode  : 0x42b8001e fatal error
Error Type        : FATAL error
PhyPortLayer      : Fibre Channel
Port(s) Affected  : fc9/41-48
Error Description : F16_PLDA_RETRY_MERR
DSAP              : 0 (0x0)
Time              : Mon Jan  6 22:22:32 2025
                    (Ticks: 677CAC08 jiffies)

A module reset is seen in the show logging nvram:

`show logging nvram`
2025 Jan  6 22:22:32 WTXA19710H15 %MODULE-2-MOD_SOMEPORTS_FAILED: Module 9 (Serial number: JAE18280N1K) reported failure on ports fc9/41-48 (Fibre Channel) due to fatal error in device DEV_F16_CMN (device error 0xccc05600)
2025 Jan  6 22:22:33 WTXA19710H15 %CALLHOME-2-EVENT: PORT_FAILURE
`show logging log`
2025 Jan  6 22:22:32 WTXA19710H15 %MODULE-2-MOD_SOMEPORTS_FAILED: Module 9 (Serial number: JAE18280N1K) reported failure on ports fc9/41-48 (Fibre Channel) due to fatal error in device DEV_F16_CMN (device error 0xccc05600)
2025 Jan  6 22:22:32 WTXA19710H15 %PORT-CHANNEL-5-PORT_DOWN: port-channel57: fc9/48 is down
2025 Jan  6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1%$ Interface fc9/48 is down (Hardware Failure) port-channel57 ISL to WTXA19710C02 fc7/22 
2025 Jan  6 22:22:33 WTXA19710H15 %CALLHOME-2-EVENT: PORT_FAILURE
2025 Jan  6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1400%$ Interface fc9/47 is down (Hardware Failure)  ltx15brwccas01_h0 
2025 Jan  6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1%$ Interface fc9/46 is down (Hardware Failure)   
2025 Jan  6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1%$ Interface fc9/45 is down (Hardware Failure)   
2025 Jan  6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1400%$ Interface fc9/44 is down (Hardware Failure)   
2025 Jan  6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1400%$ Interface fc9/43 is down (Hardware Failure)   
2025 Jan  6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1400%$ Interface fc9/42 is down (Hardware Failure)  ltx14brwccas02_h0 
2025 Jan  6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1400%$ Interface fc9/41 is down (Hardware Failure)  ltx14brwccas01_h0 

 

Cause

The DEV_F16_CMN error on a Cisco MDS 9000 series switch typically indicates a hardware issue related to the F16 ASIC. This error often results in the module rebooting due to an unrecoverable multi-bit Error-Correcting Code (ECC) error.

Resolution

The only way to recover an interface from hw_Failure is to disruptively reload the module.

#reload module x

If the interfaces are in a temporary hardware failure, status is recoverable by module reload. If the interfaces have a permanent hardware failure, then proceed with module replacement.

 

WARNING: The activity is disruptive and should be performed during the maintenance window.

 

Additional Information

SR #203555104 

Affected Products

Connectrix MDS-Series Hardware
Article Properties
Article Number: 000271449
Article Type: Solution
Last Modified: 03 Feb 2025
Version:  1
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.