PowerProtect Data Manager. Backup fails with Error: ABV0022. VDDK Error: 14009....
Summary: PPDM VM VADP Backup fails with the following error: Backup has FAILED. Unable to backup virtual disk "Hard disk 2". Unable to initialize Block Reader. Unable to open source VMDK '[VxRail-Virtual-SAN-Datastore-xxxx] xxxx/VM1_5.vmdk'. VDDK Error: 14009: The server refused connection. (500) ...
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
PPDM VM backup using VADP fails with the error below:
Warnings : Unable to collect list of allocated blocks for 'Hard disk 2'. Unable to query allocated blocks of virtual disk '[VxRail-Virtual-SAN-Datastore-xxxxx] xxxxx/VM1_5.vmdk'. Unable to open source VMDK '[VxRail-Virtual-SAN-Datastore-xxxxx] xxxxx/VM1_5.vmdk'. VDDK Error: 14009: The server refused connection Error : Backup has FAILED. Unable to backup virtual disk "Hard disk 2". Unable to initialize Block Reader. Unable to open source VMDK '[VxRail-Virtual-SAN-Datastore-xxxxx] xxxxx/VM1_5.vmdk'. VDDK Error: 14009: The server refused connection. (500) ErrorCode : ABV0022The hostd.log on the esxi host has the following error messages:
YYYY-MM-DDThh:mm:ss. info hostd[2101627] [Originator@6876 sub=DiskLib opID=lro--xxxxx] DISKLIB-CTK : Could not open change tracking file "/vmfs/volumes/vsan:xxxxx/yyyyy/VM1_5-ctk.vmdk": Could not open or create change tracking file.
Cause
Issue at Vmware level with CBT (Change Block Tracking)
Resolution
Contact Vmware Support to resolve the Change Block Tracking failure for this VM. Also review VMware Article https://kb.vmware.com/s/article/2139574
to reset CBT
Affected Products
PowerProtect Data ManagerArticle Properties
Article Number: 000219544
Article Type: Solution
Last Modified: 16 Nov 2023
Version: 1
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.