Data Protection Advisor – fel vid schemalagda rapporter – generering eller publicering av schemalagd rapport för Data Protection Advisor

Summary: Schemalagda rapporter har fel: "Generation or publication of the Data Protection Advisor scheduled report 'report name' failed."

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Schemalagda rapporter visas inte korrekt.
Istället visas följande meddelande i e-post:
"Generation or publication of the Data Protection Advisor scheduled report 'report name' failed. The DPA Installation and Administration Guide Troubleshooting section provides information. Please contact an Administrator."



Följande fel observeras i server.log 
2023-08-25 02:00:13,808 ERROR [org.jboss.as.ejb3.invocation] (<report name>:2eccb637-fd75-4dd7-b8af-5b7f4fc037df:Sched) JBAS014134: EJB Invocation failed on component RunControlPanelCommandsBean for method public abstract java.util.Map com.emc.dpa.command.reporter.RunControlPanelCommands.publishControlPanel(java.util.UUID,com.emc.dpa.reporter.datamodel.RunControlPanelParameters,java.util.List) throws java.lang.Exception: javax.ejb.EJBException: java.lang.IllegalStateException: Report with id 070f6914-b5f0-4a0a-8c04-1c6394eebf33: <report> has failed submitting job into report engine, please try again



Server.log på programservern:
<install dir>/dpa/services/logs/server.log

Cause

Det här är ett känt problem som åtgärdas under följande tekniska eskalering:
DCE-6025 – schemalagd instrumentpanel misslyckas med misslyckad inlämning av jobb i rapportmotorn

Resolution

Uppgradera till 19.9 b67 för att inkludera korrigeringen.