2U enclosure Ops panel
The front of the enclosure has an Ops panel that is located on the left ear flange of the 2U chassis.
The Ops panel is a part of the enclosure chassis, but is not replaceable on-site.
The Ops panel provides the functions that are shown and described in the following figure and table.
Table 1. Ops panel functions—2U enclosure front panelNo.
| Indicator
| Status
|
---|
1
| System power
| Constant green: at least one PCM is supplying power
Off: system not operating regardless of AC present
|
2
| Status/Health
| Constant blue: system is powered on and functioning normally
Blinking blue (2 Hz): Enclosure management is busy, for example when booting or performing a firmware update
Constant amber: module fault present
Blinking amber: logical fault (2 s on, 1 s off)
|
3
| Unit identification display
| Green seven-segment display that shows the numerical position of the enclosure in the cabling sequence. The UID is also called the enclosure ID.
|
4
| Identity
| Blinking blue: system ID locator is activated (1 s on, 1 s off)
Off: Normal state
|