Configure two ports as FC and two ports as iSCSI per controller
Perform the following steps on each controller to configure two ports as FC and two ports as iSCSI:
In the Welcome panel, select
System Settings, and then click the
Ports tab.
From the Host Post Mode list, select
FC-and-iSCSI.
NOTE:Ports 0 and 1 are FC ports. Ports 2 and 3 are iSCSI ports.
Set the FC port-specific options:
Set the
Speed option to the proper value to communicate with the host, or to auto, which auto-negotiates the proper link speed. A speed mismatch prevents communication between the port and host. Set a speed only if you want to force the port to use a known speed.
Set the
FC Connection Mode to either point-to-point or auto:
point-to-point: Fibre Channel point-to-point.
auto: Automatically sets the mode that is based on the detected connection type.
Set the iSCSI port-specific options:
Table 1. iSCSI port-specific options
IP Address
For IPv4 or IPv6, the port IP address. For corresponding ports in each controller, assign one port to one subnet and the other port to a second subnet. Ensure that each iSCSI host port in the storage system is assigned a different IP address. For example, in a system using IPv4:
Controller A port 2: 10.10.10.100
Controller A port 3: 10.11.10.120
Controller B port 2: 10.10.10.110
Controller B port 3: 10.11.10.130
Netmask
For IPv4, subnet mask for assigned port IP address.
Gateway
For IPv4, gateway IP address for assigned port IP address.
Default Router
For IPv6, default router for assigned port IP address.
In the Advanced Settings section of the panel, set the options that apply to all iSCSI ports:
Enable Authentication (CHAP). Enables or disables use of Challenge Handshake Authentication Protocol. Enabling or disabling CHAP in this panel updates the setting in the Configure CHAP panel (available in the Hosts topic by selecting
Action > Configure CHAP. CHAP is disabled by default.
Link Speed.
auto—Auto-negotiates the proper speed.
1 Gb/s— This setting does not apply to 10 Gb/sec HBAs.
Enable Jumbo Frames: Enables or disables support for jumbo frames. Allowing for 100 bytes of overhead, a normal frame can contain a 1400-byte payload whereas a jumbo frame can contain a maximum 8900-byte payload for larger data transfers.
NOTE:Use of jumbo frames can succeed only if jumbo-frame support is enabled on all network components in the data path.
iSCSI IP Version: Specifies whether IP values use Internet Protocol version 4 (IPv4) or version 6 (IPv6) format. IPv4 uses 32-bit addresses. IPv6 uses 128-bit addresses.
Enable iSNS: Enables or disables registration with a specified Internet Storage Name Service server, which provides name-to-IP-address mapping.
iSNS Address: Specifies the IP address of an iSNS server.
Alternate iSNS Address: Specifies the IP address of an alternate iSNS server, which can be on a different subnet.
CAUTION:Changing IP settings can cause data hosts to lose access to the storage system.
Perform one of the following:
To save your settings and continue configuring your system, click
Apply.
To save your settings and close the panel, click
Apply and Close.
A confirmation panel is displayed.
Click
OK to save your changes. Otherwise, click
Yes.