System.Power.Redundancypolicy (Read or Write)

Table 1. Details of System.Power.Redundancypolicy The following table provides the details of System.Power.Redundancypolicy attribute:
Description Selects the redundancy policy.
Legal Values
  • 255 — N/A, for the systems that are not supported
  • 0 — Not Redundant — In this mode, even if one PSU stops functioning, the server is automatically turned off.
  • 1 — Input Power Redundant — In this mode, the system is functional even if one PSU input circuit stops functioning, provided the PSUs are connected to different input circuits. This is also called AC redundancy.
  • 2 — PSU Redundant — Available only on systems with four PSUs. This is also called DC redundancy. This is only valid in a 2+1 PSU configuration. In this mode, the system is functional even if one PSU stops functioning.
Default Value N/A
Write Privilege Login and configure iDRAC
License Required iDRAC Express or iDRAC Enterprise
Dependency None

NOTE: : In a two PSU system, you must set the primary PSU (that must be ON). In a four PSU system, you must set the pair of PSUs (1+3 or 2+4) that must be ON.