iDRAC 8/7 v2.70.70.70 RACADM CLI Guide

PDF

getsensorinfo

Table 1. Details of getsensorinfoThe following table provides the details of getsensorinfo subcommand:
Description Displays the status for system sensors.

NOTE: : For Dell PowerEdge FX2 chassis with FM120x4 server, the power related information is not displayed.

NOTE: : General purpose graphical processing unit (GPGPU) status is displayed only on PowerEdge C4130 servers.

Synopsis
  • racadm getsensorinfo
  • racadm getsensorinfo -c
Input -c — Compact output format.

NOTE: : Chassis Controller is supported only on Dell PowerEdge FX2 and GPU sensors are displayed only on PowerEdge C4130 servers.

Table 2. ExampleThe following table shows the example for Sensor name and status:
<Num> <sensorName> <status>
1 IO-Cable OK
2 FPC-Cable OK
Table 3. Sensor Type
racadm getsensorinfo
Sensor Type : POWER
<Sensor Name> <Status> <Type>
PS1 Status Present AC
Table 4. Sensor infoSensor info
<Sensor Name> <Status> <Reading> <lc> <uc> <Inc>[R/W] <Unc>[R/W]
System Board Inlet Temp Ok 20 C -7 C 47 C 3 C [Y] 42C [Y]
System Board Exhaust Temp Ok 19 C 0 C 75 C 0 C [N] 70 C [N]
CPU1 Temp Ok 59 C 3 C 97 C 8 C [N] 92 C [N]
Table 5. Temperature sensorSensor Type : TEMPERATURE
Sensor Type : FAN
<Sensor Name> <Status> <Reading> <lc> <uc> <PWM %>
System Board Fan1 RPM Ok 5880 RPM 600 RPM NA 21%
System Board Fan2 RPM Ok 6000 RPM 600 RPM NA 0%
System Board Fan3 RPM Ok 5880 RPM 600 RPM NA 0%
System Board Fan4 RPM Ok 5880 RPM 600 RPM NA 0%
System Board Fan5 RPM Ok 5640 RPM 600 RPM NA 144%
System Board Fan6 RPM Ok 5880 RPM 600 RPM NA 152%
Table 6. Voltage sensor
Sensor Type : VOLTAGE
<Sensor Name> <Status> <Reading> <lc> <uc>
CPU1 VCORE PG Ok Good NA NA
System Board 3.3V PG Ok Good NA NA
System Board 5V AUX PG Ok Good NA NA
CPU1 M23 VPP PG Ok Good NA NA
System Board 1.05V PG Ok Good NA NA
CPU1 M23 VDDQ PG Ok Good NA NA
CPU1 M23 VTT PG Ok Good NA NA
System Board 5V SWITCH PG Ok Good NA NA
System Board VCCIO PG Ok Good NA NA
System Board 2.5V AUX PG Ok Good NA NA
CPU1 M01 VDDQ PG Ok Good NA NA
System Board NDC PG Ok Good NA NA
CPU1 M01 VPP PG Ok Good NA NA
System Board 1.5V PG Ok Good NA NA
System Board PS2 PG Fail Ok Good NA NA
System Board PS1 PG Fail Ok Good NA NA
System Board 1.5V AUX PG Ok Good NA NA
CPU1 M01 VTT PG Ok Good NA NA
PS1 Voltage 1 Ok 240 V NA NA
System Board DIMM PG Ok Good NA NA
Table 7. Current sensor
Sensor Type : CURRENT
<Sensor Name> <Status> <Reading> <lc> <uc> <Inc> [R/W] <unc> [R/W]
PS1 Current 1 Ok 0.4 Amps NA NA 0 Amps [N] 0 Amps [N]
System Board Pwr Consumption Ok 56 Watts NA 1386 Watts 0 Watts [N] 1260 Watts [N]
Table 8. PROCESSOR sensor
Sensor Type : PROCESSOR
<Sensor Name> <Status> <State> <lc> <uc>
CPU1 Status Ok Presence Detected NA NA
CPU2 Status N/A Absent NA NA
Table 9. MEMORY sensor
Sensor Type : MEMORY
<Sensor Name> <Status> <State> <lc> <uc>
DIMM A1 N/A Presence Detected NA NA
DIMM A2 N/A Absent NA NA
DIMM A3 Ok Absent NA NA
DIMM A4 N/A Absent NA NA
DIMM A5 N/A Absent NA NA
DIMM A6 N/A Absent NA NA
DIMM A7 N/A Absent NA NA
DIMM A8 N/A Absent NA NA
DIMM A9 N/A Absent NA NA
DIMM A10 N/A Absent NA NA
DIMM A11 N/A Absent NA NA
DIMM A12 N/A Absent NA NA
DIMM B1 N/A Absent NA NA
DIMM B2 N/A Absent NA NA
DIMM B3 N/A Absent NA NA
DIMM B4 N/A Absent NA NA
DIMM B5 N/A Absent NA NA
DIMM B6 N/A Absent NA NA
DIMM B7 N/A Absent NA NA
DIMM B8 N/A Absent NA NA
DIMM B9 N/A Absent NA NA
DIMM B10 N/A Absent NA NA
DIMM B11 N/A Absent NA NA
DIMM B12 N/A Absent NA NA
Table 10. Chassis Controller sensor
Sensor Type : Chassis Controller
<Sensor Name> <Status> <State>
Chassis Controller OK OK
/tmp # vi idraclogs
4 23:09:39 idrac8 L4, S3 [2440]: sessionmanagement_dmmapping_thread() confd (2)
4 23:09:39 idrac8 L4, S3 [2440]: request.command is 13
4 23:09:39 idrac8 L4, S3 [10297]: AddMessageToLclogEI() Obtained MUT Flag
4 23:09:39 idrac8 L4, S3 [10297]: ___ AddMessageToLclogEI : DCLCLWRAPCreateTLVLi
4 23:09:39 idrac8 L4, S3 [10297]: GetSledType() shmStatus 0 shmData0
4 23:09:39 idrac8 L5, S3 [10297]: RacadmcheckRSMStatus: This is RSM capable syst
4 23:09:40 idrac8 L4, S3 [10297]: ret is 0
4 23:09:40 idrac8 L4, S3 [10297]: probename is Chassis Controller
4 23:09:40 idrac8 L4, S3 [10297]: pCMCStatusobj->offsetKey is 24
4 23:09:40 idrac8 L4, S3 [10297]: pCMCStatusobj->sensorValue is 0
4 23:09:40 idrac8 L4, S3 [10297]: MAP Uninitialized, time to uninit = 0 millisec
4 23:09:40 idrac8 L4, S3 [10297]: RACADM total execution time: 1680 milliseconds

Table 11. Battery sensor
Sensor Type : BATTERY
<Sensor Name> <Status> <Reading> <lc> <uc>
System Board CMOS Battery Ok Present NA NA
PERC1 ROMB Battery Ok Unknown NA NA
PERC2 ROMB Battery Ok Unknown NA NA
Table 12. PERFOMANCE sensor
Sensor Type : PERFOMANCE
<Sensor Name> <Status> <Status> <lc> <uc>
System Board Power Optimized Ok Not Degraded NA NA
Table 13. INTRUSION sensor
Sensor Type : INTRUSION
<Sensor Name> <Intrusion> <Status>
System Board Intrusion Closed Power ON
Table 14. REDUNDANCY sensor
Sensor Type : REDUNDANCY
<Sensor Name> <Status> <Type>
System Board Fan Redundancy Full Redundant Fan
System Board PS Redundancy Disabled PSU
Table 15. SYSTEM PERFORMANCE sensor
Sensor Type : SYSTEM PERFORMANCE
<Sensor Name> <Status> <Reading> <lc> <uc> <Inc> [R/W] <unc> [R/W]
System Board CPU Usage Non-Critical 0% 0% 100% 0% [N] 99% [Y]
System Board IO Usage Non-Critical 0% 0% 100% 0% [N] 99% [Y]
System Board MEM Usage Non-Critical 0% 0% 100% 0% [N] 99% [Y]
System Board SYS Usage Non-Critical 0% 0% 100% 0% [N] 99% [Y]