Terminating a copy session deletes the pairing information in the array and removes any hold on the target device. Terminating a session while the device pairs are in the
CopyInProg state causes the session to end. If the application has not finished accessing all of the data, the target copy is not a full copy.
The
symclone terminate command is allowed for all clone pair states.
Examples
To terminate the copy session for device pair, enter:
symclone -g ProdDB terminate
NOTE A created and activated copy session may be terminated, but the data on the target device is not valid unless the device state is
COPIED.
If the state is
CopyInProg, then apply the
-symforce option to terminate the session. This leaves the target copy as an incomplete copy.
If the
-not_ready option is applied to the copy session, Solutions Enabler leaves the target devices in their prior
Ready or
NotReady state at the completion of the terminate operation. If the
-not_ready option is not applied to the copy session, Solutions Enabler leaves the target devices in the
Ready state at the completion of the terminate, regardless of their state prior to the terminate operation.