Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell Storage Manager 2020 R1 Administrator's Guide

Modify the iSCSI Window Size for an iSCSI Fault Domain

The window size specifies the amount of data that can be in transit at any given time.

Steps

  1. If the Dell Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
  2. Click the Storage tab.
  3. In the Storage tab navigation pane, expand Fault Domains, then expand iSCSI and click the fault domain.
  4. In the right pane, click Edit Settings.
    The Edit Fault Domain Settings dialog box opens.
  5. Click Edit Advanced Port Settings.
    The Edit Advanced Port Settings dialog box opens.
  6. In the Window Size field, type a value for the window size.
    • Allowed values are 16 KB to 32 MB.
    • The window size must be divisible by 16 KB.
  7. Click OK to close the Edit Advanced Port Settings dialog box.
  8. Click OK.