Dell PowerEdge FN I/O Module Command Line Reference Guide 9.10(0.0)

PDF

show environment

Displays the system component status (for example, temperature or voltage).

Syntax show environment [all | stack-unit unit-id]
Parameters
all Enter the keyword all to view all components.
stack-unit unit-id Enter the keywords stack-unit then the unit-id to display information on a specific stack member. The range is from 0 to 5.
thermal sensor Enter the keywords thermal-sensor to view all components.
Command Modes
  • EXEC
  • EXEC Privilege
Supported Modes All Modes
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.4(0.0) Supported on the FN I/O Aggregator.
8.3.17.0 Supported on the M I/O Aggregator.
Example (all)
Dell#show environment all
                                             
                                             -- Unit Environment Status --
                                             Unit  Status  Temp  Voltage TempStatus
                                             --------------------------------------
                                             * 1   online   66C   ok       2
                                             * Management Unit
                                             -- Thermal Sensor Readings (deg C) --
                                             Unit Sensor0 Sensor1 Sensor2 Sensor3 Sensor4 Sensor5 Sensor6 Sensor7
                                             Sensor8 Sensor9
                                             -----------------------------------------------------------------
                                             1     51      51      63     61      61       61      67     61  
                                             64      66
                                             Dell#
                                          
Example (stack-unit)
Dell#show environment stack-unit
                                             
                                             -- Unit Environment Status --
                                             Unit  Status     Temp   Voltage  TempStatus
                                             ------------------------------------------
                                             * 1  online       66C   ok       2
                                             * Management Unit
                                             Dell#
                                          
Example (thermal-sensor)
Dell#show environment thermal-sensor 
                                             
                                             -- Thermal Sensor Readings (deg C) --
                                             Unit Sensor0 Sensor1 Sensor2 Sensor3 Sensor4 Sensor5 Sensor6 Sensor7
                                             Sensor8 Sensor9
                                             -----------------------------------------------------------------
                                             1    51      51       64      61       61      61     67     61 
                                             64     66
                                             Dell#
                                          

Califique este contenido

Preciso
Útil
Fácil de comprender
¿Este artículo fue útil?
0/3000 characters
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Seleccione si el artículo fue útil o no.
  Los comentarios no pueden contener estos caracteres especiales: <>"(", ")", "\"