Dell PowerEdge FN I/O Module Configuration Guide 9.10(0.0)

PDF

Creating an FCoE Map

An FCoE map consists of the following elements.

  • An association between the dedicated VLAN used to carry FCoE traffic and SAN fabric where the storage arrays are installed. Use a separate FCoE VLAN for each fabric to which FCoE traffic is forwarded. Any non-FCoE traffic sent on a dedicated FCoE VLAN is dropped.
  • The FC-MAP value used to generate the fabric-provided MAC address (FPMA). The server uses the FPMA to transmit FCoE traffic to the fabric. You can associate an FC-MAP with only one FCoE VLAN and vice versa.
  • FCF priority: a CNA server uses the priority to select an upstream FCoE forwarder (FCF).
  • FIP keepalive (FKA) advertisement timeout.

The values for the FCoE VLAN, fabric ID, and FC-MAP must be unique. Apply an FCoE map on downstream server-facing Ethernet ports and upstream fabric-facing Fibre Channel ports.

  1. Create an FCoE map which contains parameters used in the communication between servers and a SAN fabric. CONFIGURATION mode fcoe-map map-name
  2. Configure the association between the dedicated VLAN and the fabric where the desired storage arrays are installed. FCoE MAP mode fabric-id fabric-num vlan vlan-id The fabric and VLAN ID numbers must be the same. The fabric and VLAN ID range is from 2 to 4094. For example:
    fabric id 10 vlan 10
  3. Add a text description of the settings in the FCoE map. FCoE MAP mode description text The maximum is 32 characters.
  4. Specify the FC-MAP value used to generate a fabric-provided MAC address, which is required to send FCoE traffic from a server on the FCoE VLAN to the FC fabric specified in Step 2. FCoE MAP mode fc-map fc-map-value You must enter a unique MAC address prefix as the FC-MAP value for each fabric. The range is from 0EFC00 to 0EFCFF. The default is none.
  5. Configure the priority used by a server CNA to select the FCF for a fabric login (FLOGI). FCoE MAP mode fcf-priority priority The range is from 1 to 255. The default is 128.
  6. Enable the monitoring FIP keep-alive messages (if it is disabled) to detect if other FCoE devices are reachable. FCoE MAP mode keepalive The default is FIP keep-alive monitoring is enabled.
  7. Configure the time interval (in seconds) used to transmit FIP keepalive advertisements. FCoE MAP mode fka-adv-period seconds The range is from 8 to 90 seconds. The default is 8 seconds.

Califique este contenido

Preciso
Útil
Fácil de comprender
¿Este artículo fue útil?
0/3000 characters
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Seleccione si el artículo fue útil o no.
  Los comentarios no pueden contener estos caracteres especiales: <>"(", ")", "\"