Dell PowerEdge FN I/O Module Configuration Guide 9.10(0.0)

PDF

Displaying the Fabric Parameters

To display information on switch-wide and interface-specific fabric parameters, use the show commands in the following table.

Examples of these show commands follow this table.

Command Description
show config Displays the fabric parameters.
show fcoe-map Displays the fcoe-map.
show fc ns switch Display all the devices in name server database of the switch.
show fc ns switch brief Display all the devices in name server database of the switch - brief version.
show fc zoneset Displays the zoneset.
show fc zoneset active Displays the active zoneset.
show fc zone Displays the configured zone.
show fc alias Displays the configured alias.
show fc switch Displays the FC Switch mode and world wide name.

Example of the show config Command

Dell(conf-fcoe-SAN_FABRIC)#show config 
                                 !
                                 fcoe-map SAN_FABRIC
                                 description SAN_FABRIC
                                 fc-map 0efc00
                                 fabric-id 1002 vlan 1002
                                 !
                                 fc-fabric
                                 default-zone-allow all
                                 Dell(conf-fcoe-SAN_FABRIC)#
                              

Example of the show fcoe-map Command

Dell(conf)#do show  fcoe-map 
                                 
                                 Fabric Name        map                     
                                 
                                 Fabric Type        Fport                   
                                 Fabric Id          1002  
                                 Vlan Id            1002  
                                 Vlan priority      3     
                                 FC-MAP             0efc00
                                 FKA-ADV-Period     8     
                                 Fcf Priority       128   
                                 Config-State       ACTIVE          
                                 Oper-State         UP              
                                 =======================================================
                                 Switch Config Parameters
                                 =======================================================
                                 DomainID           2     
                                 =======================================================
                                 Switch Zoning Parameters
                                 =======================================================
                                 Default Zone Mode:      Deny
                                 Active Zoneset:         set
                                 =======================================================
                                 Members            
                                 Fc 0/9 
                                 Te 0/2 
                                 =======================================================
                                 =======================================================
                              

Example of the show fc ns switch Command

Dell(conf)#do show fc ns sw
                                 
                                 Total number of devices =   1
                                 
                                 Switch Name                     28:4e:55:4c:4c:29:00:00
                                 Domain Id                       2     
                                 Switch Port                     4
                                 FC-Id                           02:04:03
                                 Port Name                       20:01:d4:ae:52:44:37:b2
                                 Node Name                       20:00:d4:ae:52:44:37:b2
                                 Class of Service                8     
                                 Symbolic Port Name              Broadcom Port0 pWWN 20:01:d4:ae:52:44:37:b2
                                 Symbolic Node Name              Broadcom BCM57810 FCoE 7.6.3.0 7.6.59.0 WIN-KBFI7FJ2FUH
                                 Port Type                       N_Port
                              

Example of the show fc ns switch brief Command

Dell#show fc ns switch brief
                                 Total number of devices = 1
                                 Intf#  Domain FC-ID    Enode-WWPN              Enode-WWNN
                                 Fc 0/9 1      01:35:00 10:00:8c:7c:ff:17:f8:01 20:00:8c:7c:ff:17:f8:01
                                 Dell#
                              

Example of the show fc zoneset Command

Dell#show fc zoneset
                                 ZoneSetName ZoneName ZoneMember
                                 ========================================
                                 fcoe_srv_fc_tgt
                                 brcd_sanb
                                 brcd_cna1_wwpn1
                                 sanb_p2tgt1_wwpn
                                 
                                 Active Zoneset: fcoe_srv_fc_tgt
                                 ZoneName ZoneMember
                                 ========================================
                                 brcd_sanb
                                 10:00:8c:7c:ff:21:5f:8d
                                 20:02:00:11:0d:03:00:00
                                 Dell#
                              

Example of the show fc zoneset active Command

Dell#show fc zoneset active
                                 Active Zoneset: fcoe_srv_fc_tgt
                                 ZoneName  ZoneMember
                                 ==================================
                                 brcd_sanb
                                 10:00:8c:7c:ff:21:5f:8d
                                 20:02:00:11:0d:03:00:00
                                 Dell#
                              

Example of the show fc zone Command

Dell#show fc zone
                                 ZoneName  ZoneMember
                                 ==============================
                                 brcd_sanb
                                 brcd_cna1_wwpn1
                                 sanb_p2tgt1_wwpn
                                 Dell#
                              

Example of the show fc alias Command

Dell(conf)#do show fc alias 
                                 
                                 ZoneAliasName               ZoneMember
                                 =======================================================
                                 test                            
                                 20:02:d4:ae:52:44:38:4f
                                 20:34:78:2b:cb:6f:65:57
                              

Example of the show fc switch Command

Dell(conf)#do show  fc switch 
                                 Switch Mode : FPORT
                                 Switch WWN  : 10:00:aa:00:00:00:00:ac
                                 Dell(conf)#
                              

Califique este contenido

Preciso
Útil
Fácil de comprender
¿Este artículo fue útil?
0/3000 characters
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Seleccione si el artículo fue útil o no.
  Los comentarios no pueden contener estos caracteres especiales: <>"(", ")", "\"