Enabling Extended sFlow

Dell Networking OS supports extended-switch information processing only.

Extended sFlow packs additional information in the sFlow datagram depending on the type of sampled packet. You can enable the following options:
  • extended-switch — 802.1Q VLAN ID and 802.1p priority information.
  • extended-router — Next-hop and source and destination mask length.
  • extended-gateway — Source and destination AS number and the BGP next-hop.
  • Enable extended sFlow. sflow [extended-switch] [extended-router] [extended-gateway] enable By default packing of any of the extended information in the datagram is disabled.
  • Confirm that extended information packing is enabled. show sflow

Example of Verifying Extended sFlow is Enabled

The bold line shows that extended sFlow settings are enabled on all three types.

Dell#show sflow
                                 sFlow services are enabled
                                 Global default sampling rate: 4096
                                 Global default counter polling interval: 15
                                 
                                 Global extended information enabled: switch
                                 1 collectors configured
                                 Collector IP addr: 10.10.10.3, Agent IP addr: 10.10.0.0, UDP port: 6343
                                 77 UDP packets exported
                                 0 UDP packets dropped
                                 165 sFlow samples collected
                                 69 sFlow samples dropped due to sub-sampling
                                 Stackunit 1 Port set 0 H/W sampling rate 8192
                                 Tengig 1/16: configured rate 8192, actual rate 8192, sub-sampling rate 1
                                 Tengig 1/17: configured rate 16384, actual rate 16384, sub-sampling rate 2
                                 Stackunit 3 Port set 1 H/W sampling rate 16384
                                 Tengig 3/40: configured rate 16384, actual rate 16384, sub-sampling rate 1
                              

If you did not enable any extended information, the show output displays the following (shown in bold).

Dell#show sflow
                                 sFlow services are disabled
                                 Global default sampling rate: 32768
                                 Global default counter polling interval: 20
                                 
                                 Global extended information enabled: none
                                 0 collectors configured
                                 0 UDP packets exported
                                 0 UDP packets dropped
                                 0 sFlow samples collected
                                 0 sFlow samples dropped due to sub-sampling
                              

Califique este contenido

Preciso
Útil
Fácil de comprender
¿Este artículo fue útil?
0/3000 characters
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Seleccione si el artículo fue útil o no.
  Los comentarios no pueden contener estos caracteres especiales: <>"(", ")", "\"