ASDS009 및 ASDS0018 오류로 인해 Linux AIX 서버에 대한 PowerProtect 검색 작업 실패

Summary: Linux AIX 서버에 대한 PowerProtect 검색 작업이 실패하고 ASDS009 및 ASDS0018 오류가 발생합니다.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

PowerProtect Data Manager에 Linux AIX 서버를 등록한 후 후속 검색 작업이 실패하고 다음 오류가 발생할 수 있습니다.

ASDS0009
An exception occurred while discovering Applications System for AddOn FILE_SYSTEM_CLUSTER on host <Linux\AIX Server>: 
Process /opt/dpsapps/fsagent/bin/ddfscon failed with error code 1

The Application System discovery was unsuccessful.
Recommended Action: 
Check the log files at INSTALL_DIR\DPSAPPS\AGENTSERVICE\logs.
Where INSTALL_DIR is the directory on the user machine where the agent service is installed.
If the issue persists, contact Dell Customer Support.

안에 OpAgnetSVC*.log Linux AIX 서버에서 다음 오류가 발생합니다. 

[2025-09-15 21:14:37,695 GMT| 2025-09-15 16:14:37,697063 CST| DBGAPPSYSTEMSDISCOVERY| PID-3148434| TID-140737354009472| ERROR] /opt/dpsapps/agentsvc/tmp/_MEIQpKlKE/JobManager/Ops/AppSystemDiscoveryOp.pyc-run()-Line 156- GeneralError while getting applicationSystems for AddOn FILE_SYSTEM_CLUSTER.

Cause

IPv6는 /etc/hosts 누락되거나 주석 처리된 Linux AIX 서버의 파일입니다.

/etc/hosts Linux AIX 서버의 파일에는 다음 줄이 있어야 합니다.

    127.0.0.1   localhost localhost.localdomain localhost4 localhost4.localdomain4
    ::1         localhost localhost.localdomain localhost6 localhost6.localdomain6

Resolution

이 문제를 해결하려면 누락된 줄을 추가하거나 주석 처리를 제거합니다. /etc/hosts file PowerProtect 에이전트 서비스를 재시작합니다.